BRAND : Gestra
Steam Traps STERIline ® SMK 22-81, SMK 22-82
Suitable for clamp connections to DIN 32676, for pipes to DIN 11866 (DIN 11850, ISO 1127, ASME-BPE) PN 10
Description :
The thermostatic steam trap features minimum stagnant
area and a corrosion-resistant membrane regulator unaffected by waterhammer. Used for discharging condensate
and air-venting steam in sterile and aseptic applications.
The membrane regulator with rolling ball features a selfcentering valve cone that can move freely, thereby ensuring
steam-tight shut-off unaffected by dirt particles.
High response sensitivity thanks to small dimensions of the
regulator (evaporation thermostat). Automatic air-venting and
discharge of condensate without any banking-up within the
whole pressure / temperature range. The opening temperature is approximately 5 K below the boiling point.
All parts in contact with the fluid are made of stainless steel
and the body gasket is of PTFE (FPM) in accordance with
the regulations specified by the Food and Drug Administration (FDA).
The surface roughness Ra of the wetted surfaces is ? 0.8
?m, optional: ? 0.6 ?m.
The surface roughness Ra of all other surfaces is ? 1.2 ?m.
Steam Traps STERIline ® SMK 22-81, SMK 22-82
Suitable for clamp connections to DIN 32676, for pipes to DIN 11866 (DIN 11850, ISO 1127, ASME-BPE) PN 10
Description :
The thermostatic steam trap features minimum stagnant
area and a corrosion-resistant membrane regulator unaffected by waterhammer. Used for discharging condensate
and air-venting steam in sterile and aseptic applications.
The membrane regulator with rolling ball features a selfcentering valve cone that can move freely, thereby ensuring
steam-tight shut-off unaffected by dirt particles.
High response sensitivity thanks to small dimensions of the
regulator (evaporation thermostat). Automatic air-venting and
discharge of condensate without any banking-up within the
whole pressure / temperature range. The opening temperature is approximately 5 K below the boiling point.
All parts in contact with the fluid are made of stainless steel
and the body gasket is of PTFE (FPM) in accordance with
the regulations specified by the Food and Drug Administration (FDA).
The surface roughness Ra of the wetted surfaces is ? 0.8
?m, optional: ? 0.6 ?m.
The surface roughness Ra of all other surfaces is ? 1.2 ?m.