What are you looking for?

Gestra VKP41PLUSEX

BRAND : Gestra

A sure-fire way to clear test results thanks to simple handling and self-explanatory menu navigation

Details

A sure-fire way to clear test results thanks to simple handling and self-explanatory menu navigation

VKP Messung

With the GESTRA TRAPtest VKP 41plus Ex testing, recording and evaluation system, steam traps of all makes can be checked for loss of steam and banking-up of condensate - including in potentially explosive atmospheres. The associated TRAPtest software enables simple and extensive analysis of test results and a clear presentation of potential savings.

  • Choice of quick check or normal check
  • Automatic and objective evaluation of steam trap performance
  • no special knowledge required
  • Intuitive operation via touchscreen
  • Graphic presentation of readings
  • Integrated temperature measurement to detect banked-up condensate
  • Easy to use reports with calculation of steam loss and CO2 emissions
  • Large choice of languages, can be individually extended and adapted
  • Interface with MS Excel® and other file formats
  • Degree of protection IP 68 (data collector)
  • Intrinsically safe to Ex II 2G Ex ib IIC T4 Gb
Cost of steam generation:30 euros/ton
Operating hours:8,000 hours/year
Loss of steam per steam trap:3 kg/hour

Faulty steam trapsLoss per year
1720 EUR => 3.8t CO2
107.200 EUR => 38.4t CO2
5036.000 EUR => 192t CO2
200144.000 EUR => 768t CO2