The conductivity electrode LRG 16-4 together with the conductivity switch LRS 1-.. or conductivity controller LRR 1-.. is designed for measuring and monitoring electrical conductivity in conductive fluids. If used as conductivity limiter or continuous blowdown controller in steam boilers, the conductivity electrode LRG 16-4 can be used with the following equipment: Conductivity switch LRS 1-50 Conductivity controller LRR 1-50 Conductivity controller LRR 1-52

Technical data Service pressure PN 40, max. 32 bar at 238 °C Mechanical connection Screwed G 3/8 ISO 228-1 Materials Screw-in body: 1.4571, X6CrNiMoTi17-12-2 Measuring electrode: 1.4571, X6CrNiMoTi17-12-2 Electrode rod insulation: PTFE Length of measurement & installation 100, 300, 400, 500, 600, 800, 1000 and 1200 mm Cell constant 1 cm-1 Electrical connection Four-pole connector, cable glands M 16 (PG 11) with integral cable clamp Protection IP 65 to DIN EN 60529 Admissible ambient temperature Max. 70 °C Weight Approx. 0.5 kg (without T-type connector) Approvals TÜV approval acc. to VdTÜV Bulletin "Water Monitoring 100": Requirements made on water monitoring equipment Type approval no. TÜV · WÜL · XX-017, XX-018. UL/cUL (CSA) Approval: UL 508 and CSA C22.2 No. 14-13, Standards for Industrial Control Equipment. File E243189

Details

Description

The conductivity electrode LRG 16-4 together with the conductivity switch LRS 1-.. or conductivity controller LRR 1-.. is designed for measuring and monitoring electrical conductivity in conductive fluids. If used as conductivity limiter or continuous blowdown controller in steam boilers, the conductivity electrode LRG 16-4 can be used with the following equipment: Conductivity switch LRS 1-50 Conductivity controller LRR 1-50 Conductivity controller LRR 1-52

Technical data Service pressure PN 40, max. 32 bar at 238 °C Mechanical connection Screwed G 3/8 ISO 228-1 Materials Screw-in body: 1.4571, X6CrNiMoTi17-12-2 Measuring electrode: 1.4571, X6CrNiMoTi17-12-2 Electrode rod insulation: PTFE Length of measurement & installation 100, 300, 400, 500, 600, 800, 1000 and 1200 mm Cell constant 1 cm-1 Electrical connection Four-pole connector, cable glands M 16 (PG 11) with integral cable clamp Protection IP 65 to DIN EN 60529 Admissible ambient temperature Max. 70 °C Weight Approx. 0.5 kg (without T-type connector) Approvals TÜV approval acc. to VdTÜV Bulletin "Water Monitoring 100": Requirements made on water monitoring equipment Type approval no. TÜV · WÜL · XX-017, XX-018. UL/cUL (CSA) Approval: UL 508 and CSA C22.2 No. 14-13, Standards for Industrial Control Equipment. File E243189