What are you looking for?

Wilkerson WRA102BP Series High Precision Regulator

BRAND : Wilkerson

MPS-V32N-PC

MPS-V32N-PG

MPS-V32N-NC

MPS-V32N-NG

MPS-P32N-PC

MPS-P32N-PG

MPS-P32N-NC

MPS-P32N-NG

MPS-P32N-PCA


Features

Details

MPS-V32N-PC

MPS-V32N-PG

MPS-V32N-NC

MPS-V32N-NG

MPS-P32N-PC

MPS-P32N-PG

MPS-P32N-NC

MPS-P32N-NG

MPS-P32N-PCA


Features

  • Control sensitivity of .125" (.32 cm) water column allows use in precision applications.
  • A separate Control Chamber and Aspirator Tube isolate the diaphragm from the main flow to eliminate hunting and buzzing.
  • Unit construction lets you service the WRA102BP without removing it from the line.
  • Mounting Bracket is available.

Specifications

Set Point Range
2-200 PSIG
(0.15-14 bar)
(15-1400 kPa)

300-400 PSIG
(21-28 bar)
(2100-2800 kPa)

System Pressure (Maximum)
300 PSIG
(21.0 bar)
(2100 kPa)

500 PSIG
(35.0 bar)
(3500 kPa)

Flow Capacity

40 (68 m3/HR) @ 100 PSIG, (7.0 bar), (700 kPa) System Pressure

Sensitivity

.125" (.005 PSIG) (.32 cm) Water Column

Ambient Temperature

-40°F to +200°F, (-40°C to 93°C)