The NMR84 Radar Tank Gauge (RTG), with an accuracy rate of ±0.5 mm and ideally suited for stilling well applications in custody transfers, is used for high accuracy, continuous, non-contact level measurement in bulk liquid storage tanks.

The NMR84 Radar Tank Gauge (RTG), with an accuracy rate of ±0.5 mm and ideally suited for stilling well applications in custody transfers, is used for high accuracy, continuous, non-contact level measurement in bulk liquid storage tanks.

Specifications

Weight
  • Housing with electronics: approx. 12 kg (26 lb)
  • Sensor and process connection: 8.5 to 43 kg (19 to 95 lb); dependent on the device version

Enclosure

• Housing: Aluminum
• Antenna and Process Connection:
• 316L: Flange, Housing Adapter, Sensor Adapter, Antenna Retaining Ring, Antenna Extension
• PTFE: Planar Antenna
• FKM/HNBR/FFKM: Sealing Ring
• Rated IP66/68, NEMA Type 4x/6P enclosure

Flange Type
  • NPS ASME B16.5, 150 lb, 4? to 10?
  • NPS ASME B16.5, 300 lb, 4? to 8?
  • DN100/DN150, PN10/16 B1 and PN25/40 B1
  • DN200/DN250, PN16 B1
  • DN200 PN25 B1
  • UNI flange DN150/6?/150, max PN1/ Cl.14.5/1K, suitable for DN150 PN10/16, NPS 6? Cl.150, 10K 150
  • UNI flange DN200/8?/200, max PN1/ Cl.14.5/1K, suitable for DN200 PN10/16, NPS 8? Cl.150, 10K 200
  • UNI flange DN250/10?/250, max PN1/ Cl.14.5/1K, suitable for DN250 PN10/16, NPS 10? Cl.150, 10K 250
  • UNI flange DN300/12?/300, max PN1/ Cl.14.5/1K, suitable for DN300 PN10/16, NPS 12? Cl.150, 10K 300

Ambient Temperature
  • Device: -40 to +60°C (-40 to +140°F)
  • Display Module: -20 to +70°C (-4 to
    +158°F)

Primary Output

• MODBUS RS485
• V1
• 4-20mA HART Ex d/XP, RTD input
• 4-20mA HART Ex i/IS, RTD input

Range

Calibration Range: 30 m (98 ft)

Maximum Range: Depending upon configuration choices
0.8 to 20 m (2.6 to 66 ft)
0.8 to 30 m (2.6 to 98 ft)
0.8 to 40 m (2.6 to 131 ft)

Approvals

FM, IEC Ex and ATEX approvals


Options

Approvals & Certifications

FM, IEC Ex and ATEX approvals

SIL2 and SIL 3 certifications

Power Supply
  • High voltage type: 85 to 264 VAC, 50/60 Hz, 28.8 VA
  • Low voltage type: In preparation

Communication

Primary Output

  • Modbus RS485
  • V1
  • 4-20mA HART Ex d/XP, RTD input
  • 4-20mA HART Ex i/IS, RTD input

Secondary I/O Analogue

  • Ex d/XP, 1x 4-20mA HART, 1x RTD input
  • Ex d/XP, 2x 4-20mA HART, 2x RTD input
  • Ex i/IS, 1x 4-20mA HART, 1x RTD input
  • Ex i/IS, 2x 4-20mA HART, 2x RTD input
  • 1x Ex i/IS 4-20mA HART, 2x RTD input + 1x Ex d/XP 4-20mA HART

Secondary I/I Digital Ex D/XP

  • 2x relay / 2x module discrete
  • 4x relay / 4x module discrete
  • 6x relay / 6x module discrete
  • Modbus RS485
  • Modbus RS485 + 2x relay / 2x module discrete
  • Modbus RS485 + 4x relay / 4x module discrete

Housing

Transmitter Aluminum, coated, process 316/316L

Electrical
  • Thread M20, IP66/68 NEMA Type 4X/6P Encl
  • Thread M25, IP66/68 NEMA Type 4X/6P Encl.
  • Thread G1/2, IP66/68 NEMA Type 4X/6P Encl.
  • Thread G3/4, IP66/68 NEMA Type 4X/6P Encl.
  • Thread NPT1/2, IP66/68 NEMA Type 4X/6P Encl.
  • Thread NPT3/4, IP66/68 NEMA Type 4X/6P Encl.

Antenna
  • Planar 100mm/4?
  • Planar 150mm/6?
  • Planar 200mm/8?
  • Planar 250mm/10?
  • Planar 300mm/12?

Language
  • English
  • German
  • Japanese