What are you looking for?

Varec Prothermo NMT539 Average Temperature Converter

BRAND : Varec

The Prothermo NMT539 provides a single, intrinsically safe solution for average temperature and water bottom (interface) measurement. Choose the modules you need – temperature probe, water bottom sensor, converter – or combine them together into a single new instrument.

The Prothermo NMT539 provides a single, intrinsically safe solution for average temperature and water bottom (interface) measurement. Choose the modules you need – temperature probe, water bottom sensor, converter – or combine them together into a single new instrument.

Specifications

Elements/Probe

Converter Compatibility: Pt100, Cu100, Cu90, PtCu100, JPt100 (maximum 16 elements)
With probe: up to 16 Platinum (Pt. 100), Class A elements per IEC PUB 751 1995

Accuracy

Temperature Accuracy: ±0.15 °C (±0.27 °F), or better conversion accuracy based on IEC 60751 class A standard
Water Bottom: 4mm (±2mm) or better accuracy (at reference condition)

Measuring Range

Temperature probe:
?40…+100 °C (?40…+212 °F), ?55…+235 °C (?67…+455 °F), -170… +60 °C (?328…+158 °F)
Water bottom probe: 0 to +100 °C (?32 to +212 °F)

Power & Communications

DC16?30V input (DC24V ±10% is supplied by the HOST i.s. HART communication line for standard applications.)
The Prothermo NMT539 consumes an average fixed current of 6 to 12 mA depending on configuration.

Approvals

Factory Mutual (FM) ? Intrinsically Safe ? Class I, Division 1, Groups C/D
Contact Varec for ATEX and IECEx approved devices.
Housing: rated IP65 (open housing: IP20)
Probe: rated IP68

Options

01 Approvals
  • FM ? Intrinsically Safe ? Class I, Division 1, Groups C & D
  • Contact Varec for ATEX and IECEx approved devices

02 Functionality
  • Converter
  • Temperature and Converter
  • Water Bottom and Converter
  • Temperature, Water Bottom and Converter

03 Temperature Measuring Range
  • 40…+100 °C (?40…+212 °F)
  • ?55…+235 °C (?67…+455 °F)
  • ?170… +60 °C (?328…+158 °F)

04 Water Bottom Measuring Range
  • None
  • 1 m (3.3 ft)
  • 2 m (6.6 ft)

05 Cable Entry
  • Thread NPT 1/2
  • Thread M20

06 Process Connection
  • Flange JIS 10K 50A RF, Stainless steel 316
  • Flange ANSI 2? 150lbs RF, Stainless steel 316
  • Flange DIN DN50 PN10 RF, Stainless steel 316
  • Flange JPI 2? 150lbs RF, Stainless steel 316
  • Universal coupling, PF(NPS)3/4, (converter only)
  • Thread M20 (converter only)

07 Number of Elements
  • 2…Pt100 elements
  • 3…Pt100 elements
  • 4…Pt100 elements
  • 5…Pt100 elements
  • 6…Pt100 elements
  • 7…Pt100 elements
  • 8…Pt100 elements
  • 9…Pt100 elements
  • 10…Pt100 elements
  • 11…Pt100 elements
  • 12…Pt100 elements
  • 13…Pt100 elements
  • 14…Pt100 elements
  • 15…Pt100 elements
  • 16…Pt100 elements

08 Element Spacing
  • 2m (2000mm or 79?)
  • 1.5m (1500mm or 59?)
  • 1m (1000mm or 39?)
  • Custom element position & spacing
  • 3m (3000mm or 118?)

09 Probe Length
  • Probe length 3 ft to 131ft below flange to edge of probe
  • …..mm probe length
  • …..mm probe length, gas?tight feed through

10 Mounting Accessories
  • Anchor weight 7.09? tall, diameter 4.72? (180mm tall, diameter 120mm)
  • Anchor weight – Low profile to be laid on bottom of tank Length 39.37? (1000mm); Diameter 1.61? (41mm)
  • Tensioning wire + top anchor
  • Tensioning wire, wire hook, R1 top anchor




Other Suggested Products