What are you looking for?

Varec FMR62 Radar Tank Gauge

BRAND : Varec

The FMR62 Radar Tank Gauge (RTG) is designed for 80GHz level measurement in aggressive liquids or applications with hygiene requirements.

The FMR62 Radar Tank Gauge (RTG) is designed for 80GHz level measurement in aggressive liquids or applications with hygiene requirements.

Specifications

Accuracy

Measuring distance up to 0.8 m (2.62 ft): max. ±4 mm (±0.16 in) – digital, ±0.03% analog
Measuring distance > 0.8 m (2.62 ft): ±1 mm (±0.04 in), digital, ±0.02% analog
Non-repeatability – ? 1 mm (0.04 in)

Power Consumption
  • 2-wire; 4-20mA HART: < 0.9 W
  • 2-wire; 4-20mA HART, switch output:< 0.9 W
  • 2-wire; 4-20mA HART, 4-20mA: < 2 x 0.7 W

Current Consumption

HART:
Nominal current: 3.6 to 22mA. The start-up current for multidrop mode can be parametrized
(is set to 3.6mA on delivery)

Breakdown signal (NAMUR NE43): adjustable: 3.59 to 22.5mA

Temperature

+24 °C (+75 °F) ±5° F (±9° C)

Pressure

960 mbar abs. (14 psia) ±100 mbar (±1.45 psi)

Weight

2.7 – 7.4 kg (5.95 – 16.31 lb) plus flange weight

Enclosure

Degree of protection:

  • With closed housing tested according to:
    • IP68, NEMA6P (24 h at 1.83 m under water surface)
    • For plastic housing with transparent cover (display module): IP68 (24h at 1.00 m under
      water surface)
    • IP66, NEMA4X
  • With open housing: IP20, NEMA1
  • Display module: IP22, NEMA2
  • Housing GT18: 316L, corrosion resistant
  • Housing GT19: plastic
  • Housing GT20: aluminium, seawater repellent, powder coated

Antenna

IP 68 (NEMA 6P)

Ambient Temperature

Unit: -40 °F and +176 °F (-40 °C and +80 °C)
Display: -4 °F and +158 °F (-20 °C and +70 °C)

Operating Frequency

Approx. 80 GHz, up to 8 devices can be installed in the same tank

Approvals

FM, ATEX, IEC Ex, or NEPSI


Options

Approvals and Certifications

FM, CSA, ATEX, IECEx, NEPSi, KC, INMETRO, JPN, and TIIS

Antenna
  • FKM Viton GLT, –40 to 200 °C (–40 to 392 °F) (with or without gas-tight feed through)
  • FFKM Kalrez, –20 to 200 °C (–4 to 392 °F) (with or without gastight feed through)
  • PTFE cladded, –40 to 200 °C (–40 to 392 °F) (with or without gastight feed through)

Seal
  • Integrated, PEEK, 3/4?
  • Integrated, PEEK, 1-1/2?
  • PTFE cladded flush mount DN50/2?
  • PTFE cladded flush mount DN80/3?

Process Connections
  • Thread: ISO228 G3/4, ISO228 G1-1/2, ANSI MNPT3/4, ANSI MNPT1-1/2: 316L
  • Tri-Clamp ISO2852 DN40-51 (2?), ISO2852 DN70-76.1 (3?), ISO2852 DN101.6 (4?)
  • NPS Cl.150, PTFE > 316/316L; 2?, 3?, 4?, 6?
  • NPS 4? Cl.300, PTFE > 316/316L
  • PN10/16, PTFE > 316L; DN50, DN80, DN100, SN150
  • 10K, PTFE > 316L; 50A, 80A, 100A, 150A
  • DIN11851 PN25 slotted nut, PTFE > 316L; DN50, DN80
  • DN, & RF

Output Options

HART

Gland Entry

Metric, NPT, G




Other Suggested Products

Products