What are you looking for?

Kirchgaesser MID-EX-E with CANopen Electromagnetic Small Flow Meter

BRAND : Kirchgaesser

Measuring principle:
  • Electromagnetic (flow)
  • Thinfilm sensor (pressure)
  • Thermistor (temperature)
Flow measuring ranges:0...10 l/min to 0...600 l/min
Pressure measuring ranges:0...40 bar (0...4 MPa) to 0...400 bar (0...40 MPa)<...

Details

Measuring principle:
  • Electromagnetic (flow)
  • Thinfilm sensor (pressure)
  • Thermistor (temperature)
Flow measuring ranges:0...10 l/min to 0...600 l/min
Pressure measuring ranges:0...40 bar (0...4 MPa) to 0...400 bar (0...40 MPa)
Temperature measuring ranges:0...100 °C
Nominal widths:
  • DN10, DN19 and DN25
  • Optional with plug couplers DN10, DN12, DN19, DN25 or DN31
  • Optional with socket nipples DN32 and DN50 (type SSKV heavy version)
Nominal pressure ranges:100 bar (10 MPa) to 500 bar (50 MPa)
Electrical connection:Circular connector M12x1 (Binder series 763)
Output signal:CANopen
Housing:
  • Sensor: brass or bronze
  • Electronic: plastic or brass
Electrode material:1.4571 (316Ti)
Power supply:
  • MID-EX-EM*: 8.0...9.0 VDC
  • MID-EX-ET*: 8.0...13.5 VDC
Power consumption:< 1 W
Protection acc. to EN 60529:IP 65
Vibration resistance –
Endurance stress with sliding
frequency acc. to EN 60068-2-6:
  • Excitation mode: sine
  • Frequency range: 5...500 Hz
  • Amplitude: 5…15 Hz: 5.5 mm (peak), 15…500 Hz: 5 g
  • df/dt: 1 oct / min
  • Test directions: 3 directions (X, Y, Z)
  • Test duration: approx. 70 min / direction
  • Total test duration: approx. 3.5 h
  • Test temperature: room temperature
Shock resistance -
Acc. to EN 60068-2-27:
  • Excitation mode: shock half – sine
  • Shock duration: 18 ms
  • Shock amplitude: 30 g
  • No. of shocks: 3 per direction
  • Test directions: 6 directions in space (± X, ± Y, ± Z)
  • Total no. of shocks: 18
  • Test temperature: room temperature
Marking acc. to 2014/34/EU (ATEX):I M2 Ex ia I Mb (BVS 07 ATEX E 060)
Marking acc. to IECEx:
  • Ex ia I Mb (IECEx BVS 07.0010, Dekra EXAM, Germany)
  • Ex ia I (IECEx TSA 11.0043X, TestSafe, WorkCover NSW, Australia)
Ambient temperature:0...80 °C
Process temperature:0...100 °C
Measuring uncertainty:Max. ± 2 % of end value, typ. ± 1 % of end value