FQR57 / FDR57 | FTR525 |
Detection range point level: | Max. 100 m | – |
Detection range flow: | Max. 10 m, depending on bulk solids | – |
Operating frequency: | 24.05…24.25 GHz ISM | – |
Electrical connection: | - Cable gland M20
- Thread ANSI ½ NPT
- Binder connector type M12 series 713/763
- Harting connector type HAN8D
| Plug-in terminals |
Output signal: | Serial signal for the FTR525 | - 1x (optional 2x) relay SPDT
+ 4-20 mA + alarm open collector - 1x (optional 2x) solid-state relay
+ 4-20 mA + alarm open collector
|
Power supply: | Supply via the FTR525 | 24...230 VDC (-15%/+10%) resp. 42...230 VAC (-15%/+10%), 50/60Hz |
Housing: | - Polyester
- Aluminum
- Stainless steel 316L
| Polycarbonate GRP |
Process connection: | - Thread R 1½ in accordance with EN 10226
- Thread G 1½ in accordance with ISO 228-1
- Thread 1½ NPT in accordance with ANSI/ASME
| – |
Optional process connection: | - Flange
- Sight glass
- High-temperature adapter
- High-pressure adapter
- Mounting bracket
- Structured accessories FAR50, FAR51, FAR52, FAR53, FAR54 and FAR55
- Individual customer solutions
| – |
Main wetted parts: | - Contactless installation: no
- Mounting: 316Ti, PTFE or ceramic
| – |
Ambient temperature: | -40...+70 °C | -20...+60 °C |
Process temperature: | - Contactless installation: any
- Mounting: -40...+70 °C, with high-temperature adapter -40... +450 °C
| – |
Process pressure: | - Contactless installation: any
- Mounting: 0.5...6.8 bar (50...680 kPa) abs., with high-pressure adapter 0.5...21 bar (50...2100 kPa) abs.
| – |
Protection acc. to EN 60529: | IP 66 | IP 20 |
Vibration resistance - Endurance stress with sliding frequency acc. to EN 60068-2-6: | - Excitation mode: sine
- Frequency range: 10...55 Hz
- Amplitude: 0.75 mm peak constant
- Speed of sweep: 1 oct / min
- Excitation direction: 3 directions (X, Y, Z)
- Number of cycles: 20 / direction
- Test duration: approx. 1 h 38 min / direction
- Test temperature: room temperature
| – |
Marking acc. to 2014/34/EU (ATEX): | - ATEX II 1G Ex ia IIC T4 Ga / ATEX II 1D Ex ia IIIC T135°C Da
- ATEX II 1/2G Ex ia IIC T4 Ga/Gb / ATEX II 1/2D Ex ia IIIC T135°C Da/Db
(BVS 18 ATEX E 024 X) | ATEX II (1)G [Ex ia Ga] IIC / ATEX II (1)D [Ex ia Da] IIIC (BVS 18 ATEX E 024 X) |
Marking acc. to IECEx: | - IEC Ex ia IIC T4 Ga / IEC Ex ia IIIC T135°C Da
- IEC Ex ia IIC T4 Ga/Gb / IEC Ex ia IIIC T135°C Da/Db
(IECEx BVS 18.0042X) | IEC [Ex ia Ga] IIC / IEC [Ex ia Da] IIIC (IECEx BVS 18.0042X) |
Radio approval: | - EN 300440 - Short range radio devices (SRD) – radio devices for operation in a frequency range of 1 GHz to 40 GHz
- FCC Rule Parts 15C
- IC according to RSS-Gen Issue 4 and RSS-310
| – |