Measuring principle: | Electromagnetic |
Flow measuring ranges: | 0...10 l/min to 0...600 l/min |
Nominal widths: | - DN10, DN19 and DN25
- Optional with plug couplers DN10, DN12, DN19, DN25 or DN31
- Optional with socket nipples DN32 and DN50 (type SSKV heavy version)
|
Nominal pressure ranges: | 100 bar (10 MPa) to 500 bar (50 MPa) |
Electrical connection: | Hirschmann connector type G4 |
Output signal: | Provided by the Kirchgaesser evaluation and/or display unit COMBA-EX |
Housing: | - Sensor: brass or bronze
- Electronic: plastic or brass
|
Electrode material: | 1.4571 (316Ti) |
Power supply: | Provided by the Kirchgaesser evaluation and/or display unit COMBA-EX |
Power consumption: | < 1 W |
Protection acc. to EN 60529: | IP 65 |
Vibration resistance – Endurance stress with sliding frequency acc. to EN 60068-2-6: | - Excitation mode: sine
- Frequency range: 5...500 Hz
- Amplitude: 5…15 Hz: 5.5 mm (peak), 15…500 Hz: 5 g
- df/dt: 1 oct / min
- Test directions: 3 directions (X, Y, Z)
- Test duration: approx. 70 min / direction
- Total test duration: approx. 3.5 h
- Test temperature: room temperature
|
Shock resistance - Acc. to EN 60068-2-27: | - Excitation mode: shock half – sine
- Shock duration: 18 ms
- Shock amplitude: 30 g
- No. of shocks: 3 per direction
- Test directions: 6 directions in space (± X, ± Y, ± Z)
- Total no. of shocks: 18
- Test temperature: room temperature
|
Marking acc. to 2014/34/EU (ATEX): | I M2 Ex ia I Mb (BVS 07 ATEX E 060) |
Ambient temperature: | 0...80 °C |
Process temperature: | 0...80 °C |
Measuring uncertainty: | Max. ± 2 % of end value, typ. ± 1 % of end value |