What are you looking for?

HEIDENHAIN MRP 5080 Angle Encoder Module

BRAND : HEIDENHAIN

Encoder characteristics

Incremental

MRP 5080

Absolute

MRP 5010

Measuring standard

OPTODUR circular scale

DIADUR circular scale

Signal periods

30 000

16 384

System accuracy*

±2.5” or ±5”

Position error per signal period

Details

Encoder characteristics

Incremental

MRP 5080

Absolute

MRP 5010

Measuring standard

OPTODUR circular scale

DIADUR circular scale

Signal periods

30 000

16 384

System accuracy*

±2.5” or ±5”

Position error per signal period

±0.23”

±0.40”

Repeatability

From both directions: 0.3”

From both directions: 0.9”

RMS position noise

Typically 0.007”

Typically 0.020”

Interface

? 1 VPP

EnDat 2.2

Ordering designation

EnDat22

Position values per revolution

28 bits

Clock frequency

Calculation time tcal

? 16 MHz

? 5 µs

Reference marks

80 (distance-coded)

Cutoff frequency –3 dB

? 500 kHz

Electrical connection

1.5 m cable with 15-pin D-sub connector; interface electronics integrated into the connector

15-pin header; adapter cable with quick connector as accessory

Cable length

? 30 m (with HEIDENHAIN cable)

Supply voltage

DC 5 V ±0.25 V

DC 3.6 V to 14 V

Power consumption (max.)

5.25 V: ? 950 mW

3.6 V: ? 1.1 W

14 V: ? 1.3 W

Current consumption (typical)

175 mA (without load)

5 V: 140 mA (without load)

* Please select when ordering

Bearing properties

Incremental

MRP 5080

Absolute

MRP 5010

Shaft

Hollow through shaft D = 35 mm

Max. permissible axial load3)

200 N (centered load)

Max. permissible radial load3)

60 N

Max. permissible tilting torque3)

2.5 Nm

Contact stiffness

Axial: 303 N/µm

Radial: 181 N/µm

(calculated values)

Resistance to tilt

102 Nm/mrad (calculated value)

Mechanically perm. speed

300 rpm

Moment of friction

? 0.025 Nm

Starting torque

? 0.015 Nm

Max. transferable shaft torque3)

2 Nm

Moment of inertia of rotor

0.13 · 10–3 kgm2

Radial guideway accuracy

Measured at distance h = 55 mm: ? 0.20 µm (without load)

Non-reproducible radial guideway accuracy

Measured at distance h = 55 mm: ? 0.35 µm (without load)

Axial guideway accuracy

? ±0.2 µm

Axial runout of the shaft

? 5 µm

Wobble of the axis

0.7”

Vibration 55 Hz to 2000 Hz

Shock 6 ms

? 200 m/s2 (EN 60068-2-6)

? 100 m/s2 (EN 60068-2-27)

(without load)

Protection EN 605292)

IP20

IP001) or IP40

Operating temperature

Storage temperature

0 °C to 50 °C

0 °C to 50 °C

Relative air humidity

? 75 % without condensation

Mass

0.5 kg (without cable or connector)

1) Electromagnetic compatibility must be ensured in the complete system through appropriate installation measures

2) When mounted