Specifications | LC 115 | LC 115 | LC 185 |
Measuring standard Coefficient of linear expansion | DIADUR glass scale with absolute track and incremental track, grating period 20 µm ?therm 8 x 10–6 K–1 |
Accuracy grade* | ±3 µm up to 3040 mm measuring length; ±5 µm |
Measuring length ML* in mm | 140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440 1540 1640 1740 1840 2040 2240 2440 2640 2840 3040 3240 3440 3640 3840 4040 4240 |
Functional safety for applications up to | - • SIL-2 according to EN 61 508
- • Category 3, PL 'd” according to EN ISO 13 849-1:2008
| – | |
PFH | 15 x 10–9; ML > 3040 mm: 25 x 10–9 (up to 6000 m above sea level) | – | |
Safe position1) | Encoder: ±550 ?m; ML > 3040 mm: ±2050 µm (safety-related meas. step SM = 220 ?m) | – | |
| Mechanical connection: fault exclusions for loosening of the housing and scanning unit (page 21) |
Interface | EnDat 2.2 |
Ordering designation | EnDat22 | EnDat02 |
Measuring step At ±3 µm At ±5 µm | 0.001 µm 0.010 µm | 0.005 µm 0.010 µm |
Clock freq. (calc. time tcal) | ? 16 MHz (? 5 µs) | ? 2 MHz (? 5 µs) |
Incremental signals | – | ? 1 VPP (20 µm) |
Cutoff frequency –3 dB | – | ? 150 kHz |
Electrical connection | Separate adapter cable (1 m/3 m/6 m/9 m) connectable on both sides to mounting block |
Cable length | ? 100 m2) | ? 150 m2) |
Voltage supply | DC 3.6 V to 14 V |
Power consumption (max.) | 3.6 V: ? 1.1 W; 14 V: ? 1.3 W |
Traversing speed | ? 180 m/min (max. acceleration in measuring direction ? 100 m/s2) |
Required moving force | ? 4 N |
Vibration 55 Hz to 2000 Hz effecting the Shock 11 ms | Housing: ? 200 m/s2 (EN 60 068-2-6) Scanning unit: ? 200 m/s2 (EN 60 068-2-6) ? 300 m/s2 (EN 60 068-2-27) |
Operating temperature | 0 °C to 50 °C |
Protection EN 60 5293) | IP53 when installed according to instructions in the brochure, IP64 with sealing air from DA 400 |
Mass | 0.55 kg + 2.9 kg/m measuring length |
* Please select when ordering 1) Further tolerances may occur in subsequent electronics after position value comparison (contact manufacturer of subsequent electronics) 2) With HEIDENHAIN cable; clock frequency ? 8 MHz 3) In the application the LC must be protected from the intrusion of particles and liquids |