Electrical data |
Power supply type : | Direct current |
Working voltage [V]: | 5 ÷ 30 |
Current consumption [mA]: | On <= 1 mA - Off >= 3 mA @ 8.2V |
Protection class : | III |
Reverse polarity protection : | Presente |
Outputs |
Electrical design : | Namur |
Max switching frequency [Hz]: | 2000 |
Detection zone |
Switching distance-Sn [mm]: | 1 |
Real sensing distance-Sr [mm]: | 1 ±10% |
Operative distance-So [mm]: | 0 ÷ 0.81 |
Accuracy and Deviations |
Correction factor : | Stainless steel: 0.9 - Brass: 0.5 - Aluminium: 0.4 - Copper: 0.4 |
Switching point drift [%Sr]: | -10 ÷ +10 |
Repeatability [%Sn]: | < 3 |
Environmental conditions |
Temperature limits [°C]: | -25 ÷ +70 |
IP rating : | IP65-IP66-IP67 |
Mechanical data |
Housing : | Threded type |
Thread designation : | M8x1 |
Dimensions [mm]: | M8x1 - L=30 |
Materials : | Housing: Nickel-plated brass - Sensing area: POM red - Lock nuts: Nickel-plated brass |
Mounting : | Embeddable |
Weigth [g]: | 65 |
Electrical connection |
Cable : | 3 m - PVC/PVC - 2 x 0.25 mm² |
Compliance to Standards / Directives |
Directives compliance : | 2014/30/EU -Electromagnetic compatibility directive (EMC) |
Standards compliance : | EN60947-5-6 - Product standard |