Power supply : | Direct current |
Working voltage : | 8.2 Vdc (1Kohm) |
Switching distance (mm) : | 2 |
Output type : | Namur |
Hysteresis (%Sn) : | 1 ÷ 10 |
Max. switching frequency : | 2000 Hz |
Repeatability (%Sn) : | <= 3 |
Current absorption at 8.2V : | Target detected <= 1 mA - Target not detected >= 3 mA |
Led indicator : | Present |
Operating temperature limits : | -25 ÷ +60 °C |
Storage temperature limits : | -30 ÷ +70 °C |
IP rating : | IP 67 |
Housing material : | Nickelled brass |
Weight : | 70 g |
Mechanical characteristics : | M12x1 |
Connection type : | H plug |
Explosive atmosphere type : | Mixture Air/gas and/or Air/Dust |
Equipment category : | 1G / 1D |
Installation area : | Gas: Zone 0, Zone 1 and Zone 2 - Dust: Zone 20, Zone 21 and Zone22 |
Protection method : | Intrinsically safe |
Marking : | Gas: II 1G Ex ia IIC T6 Ga - Dust: II 1D Ex ia IIIC T85°C Da -25< Ta |
Safety information : | Connection to certified intrinsically safe circuits only with the following values : Uo <= 17 V , |
Conforming standard : | EN60079-0, EN60079-11 and EN60947-5-12 |
EC-tipe examination certificate - ATEX : | IMQ 13 ATEX 019 |
Certificate of conformity (CoC) - IECEx : | IECEx IMQ 13.0012X |