Electrical data |
Power supply type : | Alternating current |
Working voltage [V]: | 20 ÷ 250 |
Protection class : | III |
Outputs |
Function : | NO |
Max voltage drop [V]: | < 6 |
Max output current [mA]: | 300 |
Minimum output current [mA]: | 5 |
Max peak current [A]: | 1.5 |
Residual current [mA]: | < 1 |
Max switching frequency [Hz]: | 12 |
Detection zone |
Switching distance-Sn [mm]: | 8 |
Real sensing distance-Sr [mm]: | 8 ±10% |
Operative distance-So [mm]: | 0 ÷ 6.48 |
Accuracy and Deviations |
Correction factor : | Stainless steel: 0.9 - Brass: 0.5 - Aluminium: 0.4 - Copper: 0.4 |
Hysteresis [%Sr]: | < 10 |
Switching point drift [%Sr]: | -10 ÷ +10 |
Repeatability [%Sn]: | < 3 |
Environmental conditions |
Temperature limits [°C]: | -25 ÷ +70 |
IP rating : | IP65-IP66-IP67 |
Display and control elements |
Display : | Output switching status - 1 x LED: Yellow |
Mechanical data |
Housing : | Threded type |
Thread designation : | M18x1 |
Dimensions [mm]: | M18x1 - L=74.5 |
Materials : | Housing: Nickel-plated brass - Sensing area: POM blue - Lock nuts: Nickel-plated brass |
Mounting : | Not embeddable |
Weigth [g]: | 130 |
Electrical connection |
Cable : | 2 m - PVC/PVC - 2 x 0.50 mm² |
Compliance to Standards / Directives |
Directives compliance : | 2014/30/EU -Electromagnetic compatibility directive (EMC) 2014/35/UE -Low voltage directive (LVD) |
Standards compliance : | EN60947-5-2 - Product standard |