Product characteristics |
---|
Output signal | switching signal |
Measuring range [bar] | 0...100 |
Application |
---|
Special feature | Gold-plated contacts |
Application | for industrial applications |
Media | liquids and gases |
Conditionally suitable for | For gaseous media the application is limited to max. 25 bar. |
Medium temperature [°C] | -25...80 |
Pressure rating [bar] | 300 |
Min. bursting pressure [bar] | 650 |
Type of pressure | relative pressure |
Electrical data |
---|
Operating voltage [V] | 18...30 DC |
Current consumption [mA] | < 60 |
Min. insulation resistance [M?] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 0.2 |
Integrated watchdog | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 1 |
Outputs |
---|
Total number of outputs | 1 |
Output signal | switching signal |
Electrical design | PNP |
Number of digital outputs | 1 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range [bar] | 0...100 |
Set point SP [bar] | 1...100 |
Reset point rP [bar] | 0.5...99.5 |
In steps of [bar] | 0.5 |
Accuracy / deviations |
---|
Switch point accuracy [% of the final value] | < ± 1,0 |
Repeatability [% of the final value] | < ± 0,25; (with temperature fluctuations < 10 K) |
Temperature drift per 10 K | < ± 0.3 |
Response times |
---|
Switching frequency for a given set response time of one output | Response time (dAP) | [ms] | 3 | 6 | 10 | 17 | 30 | 60 | 125 | 250 | 500 | Switching frequency | [Hz] | 170 | 80 | 50 | 30 | 16 | 8 | 4 | 2 | 1 |
|
Response time [ms] | at rectangular pressure characteristic; switch point (SPx) = 70 %; reset point (rPx) = 30 % |
Delay time programmable dS, dr [s] | 0, 0,2,...10, 11,...50 |
Software / programming |
---|
Adjustment of the switch point | programming button |
Parameter setting options | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping |
Operating conditions |
---|
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -40...100 |
Protection | IP 67 |
Tests / approvals |
---|
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 10 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-6 HF conducted | 10 V |
|
Shock resistance | DIN IEC 68-2-27 | 50 g (11 ms) |
|
Vibration resistance | DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
|
Mechanical data |
---|
Materials | EPDM/X; FKM; PA; PBT; PC; stainless steel (1.4301 / 304) |
Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles | 100 million |
Displays / operating elements |
---|
Display | switching status | LED, red | function display | 7-segment LED display | measured values | 7-segment LED display |
|
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |