Operating voltage NEC Class 2 power source 24 V DC (-25% +33%) safety extra-low voltage (SELV)

(redundant inputs decoupled), 5 A maximum

Buffer time min. 10 ms at 24 VDC

Potential difference between input Potential difference to input voltage, +24 VDC: 32 V DC

voltage and housing Potential difference to input voltage, ground: -32 V DC

Current consumption at 24 VDC 7.0 W maximum; 24 Btu (IT)/h

Overload current protection at input non-changeable fuse

Dimensions W x H x D 47 mm x 135 mm x 111 mm 1.9 in x 5.3 in x 4.4 in

Weight 230 g 5.07 lb

Ambient temperature Surrounding air: 0 ºC to + 60 ºC 32 ºF to 140 ºF

Storage temperature Surrounding air: - 20 ºC to + 80 ºC -4 ºF to 176 ºF

Humidity up to 95% (non condensing)

Atmospheric pressure up to 2000 m (795 hPa, higher altitudes on demand)

Protection type IP 20

EMC interference proof

Discharge of static electricity

Contact discharge EN 61000-4-2 Test level 3

Air discharge EN 61000-4-2 Test level 3

Electromagnetic fields EN 61000-4-3 Test level 3

Fast transients EN 61000-4-4 Test level 3

Surge voltage symmetrical EN 61000-4-5 Test level 2

Surge voltage asymmetrical EN 61000-4-5 Test level 3

Cable-based RF faults EN 61000-4-6 Test level 3

EMC emitted immunity

EN 55022 Class A

CFR-47 Part 15 Class A

Germanischer Lloyd Rules for Classification and Construction VI - 7 - 3 Part 1<...

Details

Operating voltage NEC Class 2 power source 24 V DC (-25% +33%) safety extra-low voltage (SELV)

(redundant inputs decoupled), 5 A maximum

Buffer time min. 10 ms at 24 VDC

Potential difference between input Potential difference to input voltage, +24 VDC: 32 V DC

voltage and housing Potential difference to input voltage, ground: -32 V DC

Current consumption at 24 VDC 7.0 W maximum; 24 Btu (IT)/h

Overload current protection at input non-changeable fuse

Dimensions W x H x D 47 mm x 135 mm x 111 mm 1.9 in x 5.3 in x 4.4 in

Weight 230 g 5.07 lb

Ambient temperature Surrounding air: 0 ºC to + 60 ºC 32 ºF to 140 ºF

Storage temperature Surrounding air: - 20 ºC to + 80 ºC -4 ºF to 176 ºF

Humidity up to 95% (non condensing)

Atmospheric pressure up to 2000 m (795 hPa, higher altitudes on demand)

Protection type IP 20

EMC interference proof

Discharge of static electricity

Contact discharge EN 61000-4-2 Test level 3

Air discharge EN 61000-4-2 Test level 3

Electromagnetic fields EN 61000-4-3 Test level 3

Fast transients EN 61000-4-4 Test level 3

Surge voltage symmetrical EN 61000-4-5 Test level 2

Surge voltage asymmetrical EN 61000-4-5 Test level 3

Cable-based RF faults EN 61000-4-6 Test level 3

EMC emitted immunity

EN 55022 Class A

CFR-47 Part 15 Class A

Germanischer Lloyd Rules for Classification and Construction VI - 7 - 3 Part 1

Stability

Vibration IEC 60068-2-6 Test FC, testing level in line with IEC 61131-2

Germanischer Lloyd Guidelines for the Performance of Type Tests Part 1

Shock IEC 60068-2-27 Test Ea, testing level in line with IEC 61131-2

Network size

TP/TX port 10BASE-T/100BASE-TX

Length of a twisted pair segment 100 m (328 ft) maximum

Interfaces

8 TP/TX ports RJ45 sockets, 10/100 MBit/s

Indicator contact 1 A maximum, 24 V

Displays

Equipment status 1 x green LED P1 – power 1, supply voltage 1 present

1 x green LED P2 – power 2, supply voltage 2 present

1 x red LED FAULT – indicator contact is open and indicates error

Port status 8 x green/yellow LED DAT/STAT 1 to 8 – data, link status

Controls

8-pole DIP switch LA1 to LA8 – suppress message about the link statuses

Scope of delivery

Rail Switch RS2-TX incl.

terminal block for supply voltage

description and operating instructions

Order number

Rail Switch RS2-TX 943 686-003

Accessories

Ethernet manual 943 320-011

Manual

Basics Industrial ETHERNET and TCP/IP 280 720-834

Rail Power Supply RPS 30 943 662-003

Rail Power Supply RPS 60 943 662-001

Rail Power Supply RPS 120 943 662-011