What are you looking for?

Hirschmann Rh1-Tp/Fl Twisted Pair Industrial Hubs

BRAND : Hirschmann

Delivery informations

Availability no longer available

Product description

Description Industrial ETHERNET Rail Hub, Ethernet (10 Mbit/s)

Port type and quantity 4 x 10BASE-T, TP cable, RJ45 sockets

Type RH1-TP

Order No. 943 639-002

More Interfaces

Power supply/signaling contact 1 plug-in terminal block, 5-pin

Network size - length of cable

Twisted pair (TP) 0 - 100 m

Network size - cascadibility

Propagation equivalent TP port <-> TP port: 190 m

Path variability value TP port <-> TP port: 4 BT

Power requirements

Operating voltage 24 V DC (-25% to +30%)

Current consumption at 24 V DC max. 130 mA

Service

Diagnostics LEDs (power, data, link status), signal contact/Fault relais (24 V DC / 1 A)

Redundancy

Redundancy functions redundant 24 V power supply

Ambient conditions

Operating temperature 0 ºC to +60 ºC

Storage/transport temperature -25 ºC to +70 ºC

Relative humidity (non-condensing) 10% to 95%

MTBF 159.7 years; MIL-HDBK 217F: Gb 25 ºC

Mechanical construction

Dimensions (W x H x D) 40 mm x 125 mm x 80 mm

Mounting DIN Rail 35 mm

Weight 530 g

Protection class IP 30

Mechanical stability

IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks

IEC 60068-2-6 vibration 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/mi...

Details

Delivery informations

Availability no longer available

Product description

Description Industrial ETHERNET Rail Hub, Ethernet (10 Mbit/s)

Port type and quantity 4 x 10BASE-T, TP cable, RJ45 sockets

Type RH1-TP

Order No. 943 639-002

More Interfaces

Power supply/signaling contact 1 plug-in terminal block, 5-pin

Network size - length of cable

Twisted pair (TP) 0 - 100 m

Network size - cascadibility

Propagation equivalent TP port <-> TP port: 190 m

Path variability value TP port <-> TP port: 4 BT

Power requirements

Operating voltage 24 V DC (-25% to +30%)

Current consumption at 24 V DC max. 130 mA

Service

Diagnostics LEDs (power, data, link status), signal contact/Fault relais (24 V DC / 1 A)

Redundancy

Redundancy functions redundant 24 V power supply

Ambient conditions

Operating temperature 0 ºC to +60 ºC

Storage/transport temperature -25 ºC to +70 ºC

Relative humidity (non-condensing) 10% to 95%

MTBF 159.7 years; MIL-HDBK 217F: Gb 25 ºC

Mechanical construction

Dimensions (W x H x D) 40 mm x 125 mm x 80 mm

Mounting DIN Rail 35 mm

Weight 530 g

Protection class IP 30

Mechanical stability

IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks

IEC 60068-2-6 vibration 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge

EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)

EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line

EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line

EN 61000-4-6 conducted immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)

EMC emitted immunity

FCC CFR47 Part 15 FCC CFR47 Part 15 Class A

EN 55022 EN 55022 Class A