What are you looking for?

Hirschmann M?ce Mm3-4Fxm2 943764-101 Ethernet Modul

BRAND : Hirschmann

Multimode fiber (MM) 50/125 µm0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Power requirements
Operating voltagePower supply via the backplane of the MICE switch

Details

Multimode fiber (MM) 50/125 µm0 - 5000 m, 8 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm0 - 4000 m, 11 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Power requirements
Operating voltagePower supply via the backplane of the MICE switch
Power consumption7W
Service
DiagnosticsLEDs (power, link status, data, 100 Mbit/s, full duplex, ring port, LED test)
Ambient conditions
Standard operating temperature0 C to +60 C
Optional operating temperature-40 C to +70 C
Storage/transport temperature-40 C to +70 C
Protective paint on PCBoptional
Relative humidity (non-condensing)10% to 95%
MTBF59.5 years; MIL-HDBK 217F: Gb 25 C
Mechanical construction
Dimensions (W x H x D)38 mm x 134 mm x 118 mm
MountingBackplane
Weight180 g
Protection classIP 20
Mechanical stability
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 1 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)
EMC emitted immunity
FCC CFR47 Part 15FCC CFR47 Part 15 Class A
EN 55022EN 55022 Class A
Approvals
Safety of industrial control equipmentcUL 508
Hazardous locationsISA 12.12.01 Class 1 Div. 2 (pending)
ShipbuildingGermanischer Lloyd
Scope of delivery and accessories
Scope of deliverymodule, operating manual
Accessories to order separatelyML-MS2/MM labels