What are you looking for?

Hirschmann M-SFP-LX/LC 943015-001 Multimode Module

BRAND : Hirschmann

Product description

DescriptionSFP Fiberoptic Gigabit Ethernet Transceiver for: MICE media modules, MM4-4TX/SFP and MM4-2TX/SFP, OpenRail RS30-Switches, MACH 4000, SmartLION and GigaLION.

Details

Product description

DescriptionSFP Fiberoptic Gigabit Ethernet Transceiver for: MICE media modules, MM4-4TX/SFP and MM4-2TX/SFP, OpenRail RS30-Switches, MACH 4000, SmartLION and GigaLION.
Port type and quantity1 x 1000BASE-LX with LC connector
TypeM-SFP-LX/LC
Order No.943 015-001

Network size - length of cable

Multimode fiber (MM) 50/125 µm0 - 550 m,
0 - 11 dB link budget at 1310 nm
A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
With f/o adapter in line with IEEE 802.3-2000 clause 38 (single-mode fiber offset-launch mode conditioning patch cord)
Multimode fiber (MM) 62.5/125 µm0 - 550 m, 0 - 11 dB link budget at 1310 nm A = 1 dB/km, 3 dB reserve, B = 500 MHz x km With f/o adapter in line with IEEE 802.3-2000 clause 38 (single-mode fiber offset-launch mode conditioning patch cord)
Single mode fiber (SM) 9/125 µm0 m - 20 km,
0 - 11 dB link budget at 1310 nm
A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)

Power requirements

Operating voltagepower supply via the switch
Power consumption1 W

Service

Diagnosticsoptical input and output power, transceiver temperature

Ambient conditions

Operating temperature0 ºC to +60 ºC
Storage/transport temperature-40°C to +85°C
Relative humidity (non-condensing)10% to 95%
MTBF13 888 889 Heures

Mechanical construction

Dimensions (W x H x D)20 mm x 18 mm x 50 mm
MountingSFP slot
Weight40 g
Protection classIP 20

Mechanical stability

IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst)2 kV power line, 1 kV data line
EN 61000-4-5 surge voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1kV data line
EN 61000-4-6 conducted immunity3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz)

EMC emitted immunity

FCC CFR47 Part 15FCC CFR47 Part 15 Class A
EN 55022EN 55022 Class A

Approvals

Safety of information technology equipmentcUL 60950-1
ShipbuildingGermanischer Lloyd, ABS, BV, DNV, LR, KR, RINA