What are you looking for?

Hirschmann M-FAST SFP-SM/LC 943866-001 Connector

BRAND : Hirschmann

Type:M-FAST SFP-SM/LC
Type:M-FAST SFP-SM/LC
Description:SFP Fiberoptic Fast-Ethernet Transceiver SM
Part Number:943 866-001
Port type and quantity:1 x 100 Mbit/s with LC connector

Network size - length of cable

Single mode fiber (SM) 9/125 µm:0 - 25 km (Link Budget at 1310 nm = 0 - 13 dB; A = 0.4 dB/km, D = 3,5 ps/(nm*km))

Power requirements

Operating Voltage:power supply via the switch
Power consumption:1 W

Software

Diagnostics:Optical input and output power, transceiver temperature

Ambient conditions

MTBF (Telecordia SR-332 Issue 3) @ 25°C:652 Years
Operating temperature:0-+60 °C
Storage/transport temperature:-40-+85 °C
Relative humidity (non-condensing):5-95 %

Mechanical construction

Dimensions (WxHxD):20 mm x 18 mm x 50 mm
Weight:34 g
Mounting:SFP slot
Protection class:IP20

Mechanical stability

IEC 60068-2-6 vibration:1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock:15 g, 11 ms duration, 18 shocks

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD):6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field:10 V/m (80-1000 MHz)
EN 61000-4-4 fast transients (burst):2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage:power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 Conducted Immunity:3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)

EMC emitted immunity

EN 55022:EN 55022 Class A
FCC CFR47 Part 15:FCC 47CFR Part 15, Class A

Approvals

Safety of information technology equipment:EN60950
Hazardous locations:depending on deployed switch
Shipbuilding:depending on deployed switch