More Interfaces |
Power supply/signaling contact | 1 plug-in terminal block, 6-pin |
USB interface | 1 USB for configuration |
Network size - Length of cable |
Twisted pair (TP) | 0 - 100 m |
Singlemode fiber (SM) 9/125 | 0 - 30 km (Link Budget at 1300 nm = 0 - 16 db; A = 0.4 dB/km; BLP = 3.5 ps/(nm*km)) |
Network size - Cascadibility |
Line - / star topology | any |
Power requirements |
Operating voltage | 12/24V DC (9.6 VDC - 32 VDC), redundant |
Current consumption at 24 V DC | Max 200 mA |
Power consumption | Max. 5 W, 16.9 Btu (IT)/h |
Service |
Diagnostics | LEDs (power, link status, data, data rate) |
Ambient conditions |
Operating temperature | -40 C to +70 C |
Storage/transport temperature | -40 C to +85 C |
Relative humidity (non-condensing) | 10 % to 95% |
MTBF (Telecordia) | 954,743 hours |
Mechanical construction |
Housing dimensions (w/o terminal block) W x H x D | 56mm x 135mm x 117mm |
Mounting | DIN Rail |
Weight | 510 g |
Protection class | IP 40 |
Mechanical stability |
IEC 60068-2-27 shock | 15 g, 11 ms duration, 18 shocks |
IEC 60068-2-6 vibration | 3.5 mm, 5-8.4 Hz, 10 cycles, 1 octave/min; 1 g, 8.4-150 Hz, 10 cycles, 1 octave/min |
EMC interference immunity |
EN 61000-4-2 electrostatic discharge (ESD) | 4 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 electromagnetic field | 10 V/m (80 - 1000 MHz) |
EN 61000-4-4 fast transients (burst) | 2 kV power line, 4 kV data line |
EN 61000-4-5 surge voltage | power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
EN 61000-4-6 conducted immunity | 10 V (150 kHz - 80 MHz) |
EMC emitted immunity |
FCC CFR47 Part 15 | FCC 47 CFR Part 15 Class A |
EN 55022 | EN 55022 Class A |
Approvals |
Basis Standard | CE, FCC, EN61131 |
Safety of industrial control equipment | cUL61010-1/61010-2-201 |
Scope of delivery |
Scope of delivery | device, terminal block, safety instruction |