What are you looking for?

EKF CS5-HORN 3U Compact PCI 2 x 160MBps Dual Ultra160 SCSI Hostadapter

BRAND : EKF

Printed Circuit BoardDimensions3U Eurocard (100x160mm), front panel width 20.2mm (4HP), mechanics constructed with respect to EMC requirements, ejector lever
SCSI BusBus Type2 x ANSI SCSI Parallel Interface-3 (SPI-3) 16-bit (8-bit by adapter)
LVD (low voltage differential signal) max. 2 x 15 devices
SE (single ended) max. 2 x 15 devices (16-bit), 2 x 7 devices (8-bit)
Performance
(each Channel)
Ultra160 160MBps
Ultra2 80MBps
Wide Ultra 40MBps (16-bit), Narrow Ultra 20MBps (8-bit)
Wide Fast 20MBps (16-bit), Narrow Fast 10MBps (8-bit)
Connector SCSI_Xexternal connectors (front panel): dual VHDCI (0.8mm pitch) 68-lead receptacle, shielded, screw lock mechanism, each connector rotated 180° against the other (matching plugs with suitable asymmetric hood profile required if both connectors are engaged)
Connector SC...

Details

Printed Circuit BoardDimensions3U Eurocard (100x160mm), front panel width 20.2mm (4HP), mechanics constructed with respect to EMC requirements, ejector lever
SCSI BusBus Type2 x ANSI SCSI Parallel Interface-3 (SPI-3) 16-bit (8-bit by adapter)
LVD (low voltage differential signal) max. 2 x 15 devices
SE (single ended) max. 2 x 15 devices (16-bit), 2 x 7 devices (8-bit)
Performance
(each Channel)
Ultra160 160MBps
Ultra2 80MBps
Wide Ultra 40MBps (16-bit), Narrow Ultra 20MBps (8-bit)
Wide Fast 20MBps (16-bit), Narrow Fast 10MBps (8-bit)
Connector SCSI_Xexternal connectors (front panel): dual VHDCI (0.8mm pitch) 68-lead receptacle, shielded, screw lock mechanism, each connector rotated 180° against the other (matching plugs with suitable asymmetric hood profile required if both connectors are engaged)
Connector SCSI_Iinternal connector: 68-lead high density socket HDSUB (1.27mm pitch), screw lock mechanism 2-56 UNC, SCSI channel A only
Maximum SCSI Cable LengthLow Voltage Differential (LVD) mode: Ultra2/Ultra160 SCSI 12m
Single Ended Mode (SE) mode: Fast SCSI 3m, Ultra SCSI 3m (4 devices), 1.5m (8 devices)
Terminationactive termination, automatically enabled when board is sensed to be either end of the SCSI bus, LVD/SE self configurated termination power fused by self resetting Polyswitches 1.25A trip
Controller ChipSCSI multi-function controller SYM53C1010
maximum aggregated throughput 320MBps
PCI busmaster 64/32-bit (block transfer maximum 532MBps)
on-chip LVD/SE transceiver 2kV ESD protected
SCAM (SCSI Configured AutoMatically) level 1 functionality
target disconnect/reconnect (interrupt)
Symbios TolerANT™ SCSI signal filtering
SureLINK™ domain validation
AIP Asynchronous Information Protection
CompactPCI®
Bus
Connector J2
Connector J1
64-bit, 66MHz (532MBps)
64-bit, 33MHz (266MBps)
32-bit, 33MHz (133MBps)
PCI Burst Mode
3.3V oder 5V Interface
LED DisplayFront Panel
(each channel)
termination power
activity
LVD mode (permanent red light) or SE mode (flashing whenever SCSI Bus Busy active)
On-Board
(each channel)
local terminators active
Single Ended (SE) mode
Low Voltage Differential (LVD) mode
serial EEPROM data line access
GPIO4 (channel A: Flash BIOS programming)
Power RequirementsConnector J1+5V ± 5% 3A max. (including ext. termination power)
+3.3V ±0.3V 0.6A max.
+12V ±5% 0.05A max.
Temperature
Humidity
Commercial Grade Versionoperating temperature 0-70°C (industrial grade temperature range available on request)
humidity 5-90% non condensing
SoftwareDrivers/BIOS
Download
Symbios/LSI Logic SDMS software for Windows and many other popular operating systems
specifications are subject to change without further notice
Ordering Information
AliasOrdering NumberShort Description
HORNCS5-1-HORN3HE CompactPCI Dual Ultra160 SCSI Hostadapter 33MHz CPCI I/F
HORNCS5-2-HORN3HE CompactPCI Dual Ultra160 SCSI Hostadapter 66MHz CPCI I/F
CR9-1-ADAPTmechanical kit, converts front panel from 3U to 6U
899.3.1.02external SCSI cable assembly, VHDCI to HD-DSUB, 68-pos., length 1m, asymmetric VHDCI connector 1
899.3.2.02external SCSI cable assembly, VHDCI to HD-DSUB, 68-pos., length 2m, asymmetric VHDCI connector 1
899.3.3.02external SCSI cable assembly, VHDCI to HD-DSUB, 68-pos., length 3m, asymmetric VHDCI connector 1
899.4.010.01external SCSI cable assembly, VHDCI to VHDCI, 68-pos., length 1m, asymmetric VHDCI connectors 1
899.4.020.01same as 899.4.010.01, 2m
899.4.030.01same as 899.4.010.01, 3m


1 Whenever both external SCSI channels are in use (front panel mounted dual VHDCI receptacle), the connector style of the external VHDCI cabling set is important. Connectors conforming to the VHDCI standard are provided with an asymmetric cable entrance with respect to the center of the pin rows. However, there are cable assemblies available with symmetric VHDCI connectors, resulting in the effect that the plug partly overlaps the neighbouring VHDCI receptacle. Furthermore, cables must comply with Ultra160 LVD/SE standards.

CS5-HORN - Usage of the Dual-Port VHDCI Receptacle Together With Asymmetric Connectors

Dual-Port VHDCI Receptacle Shown Together With Asymmetric Connectors