Applications | Machine tools, Hydraulics, HVAC, Refrigeration, Process technology, Water treatment |
---|
Category | Hydraulic |
---|
Accuracy @ 25°C typ. | ± 0.5 % FS typ. |
---|
Dielectric strength | 50 VAC, 50 Hz |
---|
Measuring principle | Thin-film-on-steel |
---|
Vibration | 15 g RMS (20...2000 Hz) (EN60068-2-64) 25 g sin (80...2000 Hz), 1 oct./min, (1x @ 25°C) (EN60068-2-6) |
---|
NLH @ 25°C (BSL) typ. | ± 0.2 % FS typ. |
---|
Pressure connections | G1/4" m; G1/4" m (Manometer); G1/8" m, DIN3852-E; 1/4"NPT m; 1/4"NPT f; 1/8"NPT m; 7/16"-20UNF f, SAE J512; 7/16"-20UNF m, SAE4 (J1926); 7/16"-20UNF m, DIN3866; 9/16"-18UNF m, SAE6 (J1926); R1/4" m, DIN3858; R1/4" m, DIN299 |
---|
Media temperature | –40°C ... +125°C |
---|
Shock | 50 g / 11 ms 100 g / 6 ms Male electrical plug M12x1 (EN60068-2-27) 2) |
---|
Electrical connections | Industrial standard, contact distance 9.4 mm; M12x1; MIL-C 26482; Deutsch DT04-3P/4P; cable |
---|
Long term stability 1 year typ. | < ± 0.1 % FS typ. |
---|
Ambient temperature | –40°C ... +125°C (Cable PVC 22: -5°C ... +60°C) (Cable PUR 24: -40°C ... +70°C) (Cable Radox Tenuis 88: -40°C ... +100°C) |
---|
Protection | IP65, IP67, IP68 |
---|
Output signal | 4 ... 20 mA, 0.5 ... 4.5 VDC, 0 ... 5 VDC, 0.5 ... 5 VDC, 1 ... 5 VDC, 0.5 ... 5.5 VDC, 1 ... 6 VDC, 0 ... 10 VDC, 1 ... 10 VDC, 0.1 ... 10.1 VDC, 0.5 ... 4.5 VDC ratiometric, Switching output: 1 or 2 PNP transistors |
---|
TEB typ. @ -25 ... +85°C | ± 1.75 % FS typ. |
---|
Measuring range | 0 ... 2.5 to 0 ... 600 bar 0 ... 30 to 0 ... 7500 psi |
---|