BRAND : Trafag
Applications | Machine tools, Hydraulics, HVAC, Refrigeration, Process technology, Water treatment | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Applications | Machine tools, Hydraulics, HVAC, Refrigeration, Process technology, Water treatment |
---|---|
Category | Hydraulic |
Accuracy @ 25°C typ. | ± 0.5 % FS typ. |
Dielectric strength | 50 VAC, 50 Hz |
Measuring principle | Thin-film-on-steel |
Vibration | 15 g RMS (20...2000 Hz) (EN60068-2-64) |
NLH @ 25°C (BSL) typ. | ± 0.2 % FS typ. |
Pressure connections | G1/4" m; G1/4" m (Manometer); |
Media temperature | –40°C ... +125°C |
Shock | 50 g / 11 ms |
Electrical connections | Industrial standard, contact distance 9.4 mm; M12x1; MIL-C 26482; Deutsch DT04-3P/4P; cable |
Long term stability 1 year typ. | < ± 0.1 % FS typ. |
Ambient temperature | –40°C ... +125°C |
Protection | IP65, IP67, IP68 |
Output signal | 4 ... 20 mA, 0.5 ... 4.5 VDC, 0 ... 5 VDC, 0.5 ... 5 VDC, 1 ... 5 VDC, 0.5 ... 5.5 VDC, 1 ... 6 VDC, 0 ... 10 VDC, 1 ... 10 VDC, 0.1 ... 10.1 VDC, 0.5 ... 4.5 VDC ratiometric, |
TEB typ. @ -25 ... +85°C | ± 1.75 % FS typ. |
Measuring range | 0 ... 2.5 to 0 ... 600 bar |