Applications | Ex Zone 0, 1, 2 / Gas, Ex Underground Mining |
---|
Category | |
---|
Accuracy @ 25°C typ. | ± 0.3 % FS typ. ± 0.5 % FS typ. |
---|
Dielectric strength | 500 VAC, 50 Hz |
---|
Measuring principle | Thick-film-on-ceramic |
---|
Approval / conformity | GL, KRS Ex ATEX/IECEx, EN 60079-0/ EN 60079-11/EN 60079-26/ EN 50303 |
---|
Vibration | 10 g (50...2000 Hz) |
---|
NLH @ 25°C (BSL) typ. | ± 0.2 % FS typ. ± 0.3 % FS typ. |
---|
Pressure connections | Type 1 f, M 10x1, Type 2 m, M 22x1 |
---|
Media temperature | T4: -20°C ... +70°C T6: -20°C ... +65°C |
---|
Shock | 50 g / 3 ms |
---|
Electrical connections | Cable PUR/FEP/PE |
---|
Long term stability 1 year typ. | ± 0.2 % FS typ. ± 0.03 % FS typ. |
---|
Ambient temperature | T4: -20°C ... +70°C T6: -20°C ... +65°C |
---|
Protection | IP68 (25 bar; 250m) |
---|
Output signal | 4 ... 20 mA |
---|
TEB typ. @ -25 ... +85°C | ± 0.75 % FS typ. ± 1.5 % FS typ. |
---|
Measuring range | 0 ... 0.2 to 0 ... 10 bar |
---|