Applications | Machine tools, Hydraulics, Water treatment |
---|
Category | |
---|
Accuracy @ 25°C typ. | ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.) |
---|
Dielectric strength | Type 14/16/17/23: 100 VAC, 50 Hz Type 19: 250 VAC, 50 Hz |
---|
Measuring principle | Thick-film-on-ceramic |
---|
Vibration | 4 g (10...2000 Hz) |
---|
NLH @ 25°C (BSL) typ. | ± 0.2 FS typ. (± 0.3 FS typ.) |
---|
Pressure connections | G1/4" f; G1/4" m; G1/2" m, DIN3852-A; G1/2" m, DIN3852-E; G1/2" m, DIN3852-E, with inner cone; 1/4"NPT m, ANSI B1.20.1; 1/8"NPT m, ANSI B1.20.1; 7/16"-20UNF m, SAE4 (J1926); 7/16”-20UNF m, DIN3866; 7/16”-20UNF f, SAE J512, |
---|
Media temperature | -25°C ... +125°C |
---|
Shock | 50 g / 8 ms |
---|
Electrical connections | EN175301-803-A (DIN43650-A); M12x1; Industrial standard, contact distance 9.4 mm; Packard Metri Pack; Cable |
---|
Long term stability 1 year typ. | ± 0.2 % FS typ. |
---|
Ambient temperature | -25°C ... +125°C Cable PVC 22: -5°C ... +60°C Cable PUR 24: -20°C ... +70°C Cable Raychem 08: -20°C ... +100°C |
---|
Protection | IP65, IP67, IP68 |
---|
Output signal | 4 ... 20 mA, 0 ... 5 VDC, 1 ... 6 VDC, 0 ... 10 VDC, 0.5 ... 4.5 VDC ratiom. |
---|
TEB typ. @ -25 ... +85°C | ± 1.0 % FS typ. Range 0 ... 0.2 and 0 ... 0.4 bar: ± 2.0 % FS typ. |
---|
Measuring range | 0 ... 0.1 to 0 ... 40 bar 0 ... 1.5 to 0 ... 500 psi |
---|