Applications | Railways |
---|
Category | Railways |
---|
Accuracy @ 25°C typ. | ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.) |
---|
Measuring principle | Thick-film-on-ceramic |
---|
Approval / conformity | EN 50155 (Railway) EN 45545-2 (Fire protection) |
---|
Vibration | 15 g RMS (20...2000 Hz) (EN60068-2-64) 25 g sin (80...2000 Hz), 1 oct./min, (1x @ 25°C) (EN60068-2-6) |
---|
NLH @ 25°C (BSL) typ. | ± 0.2 FS typ. (± 0.3 FS typ.) |
---|
Pressure connections | G1/4" m; G3/4" frontal membrane |
---|
Media temperature | -25°C ... +125°C |
---|
Shock | 50 g / 11 ms 100 g / 6 ms Male electrical plug M12x1 (EN60068-2-27) 3) |
---|
Electrical connections | EN175301-803-A (DIN43650-A); M12x1; Packard Metri Pack |
---|
Long term stability 1 year typ. | ± 0.2 % FS typ. |
---|
Ambient temperature | -25°C ... +125°C |
---|
Protection | IP65, IP67 |
---|
Output signal | 4 ... 20 mA |
---|
TEB typ. @ -25 ... +85°C | ± 1.0 % FS typ. Range 0 ... 0.2 and 0 ... 0.4 bar: ± 2.0 % FS typ. |
---|
Measuring range | 0 ... 0.1 to 0 ... 60 bar 0 ... 1.5 to 0 ... 1000 psi |
---|