What are you looking for?

Solberg CSL-850-201HCB Vacuum Filter

BRAND : Solberg

Product Description

Solberg Polyester 375P Filter Element with Prefilter
Element Rating: 1500 SCFM
Surface Area ft2: 28
Inner Diameter: 8″
Outer Diameter: 11 3/4″
Height: 14 1/2″
Endcap: Galvanized metal endcaps with neoprene gaskets on open end(s)
Filtration: Polyester, 99%+ removal ...

Details

Product Description

Solberg Polyester 375P Filter Element with Prefilter
Element Rating: 1500 SCFM
Surface Area ft2: 28
Inner Diameter: 8″
Outer Diameter: 11 3/4″
Height: 14 1/2″
Endcap: Galvanized metal endcaps with neoprene gaskets on open end(s)
Filtration: Polyester, 99%+ removal efficiency to 5 micron
Temp (continuous): min -26°F (-15°C), max 220°F (104°C)
Filter change out differential: 15-20″ H2O over initial Δ P

Solberg Filter Element Features
Pleated media for high dirt holding capacity
Reinforced with epoxy coated steel wire on both sides of cloth
40 – 50% increased dust loading capacity with prefilter (part number suffix P)
Optimal surface area per given size

Polyester Media Benefits
Washable with lukewarm water & mild detergent
Less maintenance due to longer durability
Moisture resistant
Handles hot air and oil mist from unload cycle of reciprocating/piston compressor


Cleaning Solberg Filter Elements

Solberg filter elements should be cleaned or replaced once the pressure drop reaches 10 to 15-inches water column (250 – 380mm WC) above the initial pressure drop of the installation. Please note that the overall performance of a filter element is altered once cleaned; the initial pressure drop after cleaning will be greater than the original, clean pressure drop of the element. After each subsequent cleaning, the initial pressure drop will continue to increase. Under all circumstances, the initial pressure drop of the element needs to be maintained at less than 15-inches water column (380mm WC). Cleaned elements that exceed 15-inches water column (380mm WC) at start-up should be replaced with new elements.

  • Paper Element: The paper element may be lightly blown with low pressure air. It is disposable and in most cases should be replaced with a new element.
  • Polyester Element: The polyester element may be washed in warm soapy water, vacuumed, gently blown out or replaced. Use a mild detergent like Dawn liquid soap. The element should be completely dry before reinstallation. The element should be replaced after a maximum of three cleanings.
  • Polyurethane Prefilter: The prefilter may be washed as a sponge or replaced to give the element a longer service life.
  • Epoxy Coated Wire Mesh and Stainless Steel Wire Mesh Elements: Cleaning instructions similar to polyester, except mild solvents may be used.