BRAND : Olaer
Construction
Bladder accumulator with sieve plate, pressure vessel of
stainless steel 316L/1.4404, welded, heavy duty gas inlet
valve, not detechable.
Pre-Charge pressure PO
Between 0,9 P1
and 0,2 P2
, max. 20 bar
Other pressure ratios on request.
Temperature range
-20 °C to +100 °C
Other ranges on request.
Volumetric flow Q
The max. values given in the selection table apply only for a
vertical installation (hydraulic assembly downwards).
For horizontal installation or higher flow rates please contact
OLAER.
Hydraulic fluids
Hydraulic oil (mineral oil), water.
Other mediums, such as biodegradable hydraulic oil,
non-flammable liquids, emulsions, fuels, ect. should be
specified at the time of ordering.
Installation
Vertical (hydraulic assembly downwards) to horizontal.
Leave a space of 200 mm free above the gas inlet valve for
attaching the tester and pressurizer instrument.
Method of mounting
Clamps, see data sheet OSP 775
Construction
Bladder accumulator with sieve plate, pressure vessel of
stainless steel 316L/1.4404, welded, heavy duty gas inlet
valve, not detechable.
Pre-Charge pressure PO
Between 0,9 P1
and 0,2 P2
, max. 20 bar
Other pressure ratios on request.
Temperature range
-20 °C to +100 °C
Other ranges on request.
Volumetric flow Q
The max. values given in the selection table apply only for a
vertical installation (hydraulic assembly downwards).
For horizontal installation or higher flow rates please contact
OLAER.
Hydraulic fluids
Hydraulic oil (mineral oil), water.
Other mediums, such as biodegradable hydraulic oil,
non-flammable liquids, emulsions, fuels, ect. should be
specified at the time of ordering.
Installation
Vertical (hydraulic assembly downwards) to horizontal.
Leave a space of 200 mm free above the gas inlet valve for
attaching the tester and pressurizer instrument.
Method of mounting
Clamps, see data sheet OSP 775