Measured value position

Stroke range 2520…5000 mm (in 20 mm steps)

Output

Signal characteristic analog output restricted by noise or A/D converter of control unit

Voltage 0.5…9.5 VDC

Current 4…20 mA

Resolution 2520…3500 mm ? 0.5 mm 3520…5000 mm ? 1.0 mm

Power up time typ. 250 ms

Mounting zone 30 mm

Damping 63.5 mm

69.5 mm (M6 female) / 85.5 mm (M8 male)

Accuracy

Linearity 2520…3500 mm ? ±1.0 mm

3520…5000 mm ? ±2.0 mm

Hysteresis 2520…3500 mm ? ±0.5 mm

3520…5000 mm ? ±1.0 mm

Internal sample rate 2 ms

Setpoint tolerance ?1 mm

Operating conditions

Mounting position any

Operating temperature electronics ?40…+105 °C

Storage temperature ?25…+ 65 °C

Fluid temperature ?30…+ 85 °C

Dew point, humidity EN60068-2-30, 90 % rel. humidity, no condensation

Pressure without considering support tube assembly

Operating pressure ratings pressure impulse test according DIN EN ISO 19879 (Ø 10 mm pressure pipe)

PN 320 bar

Pmax 400 bar

Pstatic 550 bar

IP rating

M12 connector EN60529 (IP69K) when plugged

Sensor housing EN60529 (IP67)

Environmental testing

Shock test IEC 60068-2-27, 50 g (11 ms) single shock, 15 g (11 ms) at 1000 shocks per axis

Vibration test IEC 60068-2-64, 5 g (r.m.s.) Ø 10 mm pressure pipe (10…2000 Hz) - resonance frequencies excluded

EMC test ISO 14982 Agricultural and...

Details

Measured value position

Stroke range 2520…5000 mm (in 20 mm steps)

Output

Signal characteristic analog output restricted by noise or A/D converter of control unit

Voltage 0.5…9.5 VDC

Current 4…20 mA

Resolution 2520…3500 mm ? 0.5 mm 3520…5000 mm ? 1.0 mm

Power up time typ. 250 ms

Mounting zone 30 mm

Damping 63.5 mm

69.5 mm (M6 female) / 85.5 mm (M8 male)

Accuracy

Linearity 2520…3500 mm ? ±1.0 mm

3520…5000 mm ? ±2.0 mm

Hysteresis 2520…3500 mm ? ±0.5 mm

3520…5000 mm ? ±1.0 mm

Internal sample rate 2 ms

Setpoint tolerance ?1 mm

Operating conditions

Mounting position any

Operating temperature electronics ?40…+105 °C

Storage temperature ?25…+ 65 °C

Fluid temperature ?30…+ 85 °C

Dew point, humidity EN60068-2-30, 90 % rel. humidity, no condensation

Pressure without considering support tube assembly

Operating pressure ratings pressure impulse test according DIN EN ISO 19879 (Ø 10 mm pressure pipe)

PN 320 bar

Pmax 400 bar

Pstatic 550 bar

IP rating

M12 connector EN60529 (IP69K) when plugged

Sensor housing EN60529 (IP67)

Environmental testing

Shock test IEC 60068-2-27, 50 g (11 ms) single shock, 15 g (11 ms) at 1000 shocks per axis

Vibration test IEC 60068-2-64, 5 g (r.m.s.) Ø 10 mm pressure pipe (10…2000 Hz) - resonance frequencies excluded

EMC test ISO 14982 Agricultural and forest machines

Immunity: ISO 11452-2 (200 V/m Antenna), ISO 11452-4 (200 mA BCI)

Emissions: CISPR 25

Transiente Impulses: ISO 7637-1/2

E.S.D.: ISO/TR 10605

Materials and dimensions

Pressure pipe (Ø 10 mm) stainless steel 1.4306 / AISI 304L

Housing stainless steel 1.4305 / AISI 303

Sealing O-ring 40.87 × 3.53 mm NBR 80, back-up ring 42.6 × 48 × 1.4 PTFE

Support tube stainless steel 1.4301 / AISI 304

Support tube adapter (head/tail) stainless steel 1.4305 / AISI 303

M12 connector insert material: polyamide reinforces; O-ring 7 × 1.35 mm NBR 70; pins: brass with gold plated pins

M12 flange brass nickel-plated with O-ring 13 × 1.6 NBR 70

Electrical installation

Connector M12 male plug

Supply voltage 12 VDC (tolerance range 8…32 VDC) 24 VDC (tolerance range 8…32 VDC)

Current consumption typ. < 100 mA typ. < 50 mA

Load (output VDC) RL> 10 k? RL> 10 k?

Load current (output VDC) typ. 1 mA typ. 1 mA

Loud (output mA) RL < 250 ? RL < 500 ?

Inrush current max. 2.5 A/2 ms max. 4.5 A/2 ms

Supply voltage ripple < 1 % p-p

Power drain < 1 W

Over voltage protection (GND-VDC) up to +36 VDC

Polarity protection (GND-VDC) up to ?36 VDC

Insulation Resistance R ? 10 M? @ 60 sec

Electric strength 500 VDC (DC GND to chassis GND)