What are you looking for?

Mts Sensor MT 551218 Positions Sensor

BRAND : Mts Sensor

Input

Measured variables: Displacement

Measuring range: 50 - 2500 mm in 5 mm steps

Output

Signal characteristic: Continuously analog output restricted by noise or A/D converter of control unit

Voltage: 0.25...4.75 VDC

0.5...4.5 VDC

Current: 4...20 mA

inverse: 4.75...0.25 VDC

inverse: 4.5...0.5 VDC

inverse: 20...4 mA

Resolution: typ ± 0.1 mm

Internal Cycle Time: 2 ms

Accuracy

Linearity: .1 mm

Hysteresis: ± 0.1 mm

Setpoint Tolerance: ? 1 mm

Operating conditions

Assembly orientation: In any direction

Operating temperature electronics, storage temp.: -40°C...+105°C

Fluid temperature: -30°C...+85°C

Dew point, humidity: 90 % rel. humidity, no condensation acc. EN60068-2-30

Pressure

Operating pressure ratings:

Pressure impulse test acc.

Ø 10 mm sensor rod

PN: 350 bar

Pmax: 450 bar DIN EN ISO 19879

IP rating sensor housing

Sensor housing: IP67, EN60529

Environmental testing:

Shock:

Vibration:

EMC:

IEC-68-2-27

100 g (6 ms) single hit

50 g (11 ms) at 1000 Shocks per axis

IEC 68-2-6 (10...2000 Hz)

Ø 10 mm sensor rod 15g (r.m.s)

ISO 14982 agricultural and forestry machines

ISO 11452-2 (radiated immunity) (Increased immunity voltage output 100V/m)

ISO 11452-4 (conducted immunity)

ISO 7637-1/2 (transient Impulses)

Materials and di...

Details

Input

Measured variables: Displacement

Measuring range: 50 - 2500 mm in 5 mm steps

Output

Signal characteristic: Continuously analog output restricted by noise or A/D converter of control unit

Voltage: 0.25...4.75 VDC

0.5...4.5 VDC

Current: 4...20 mA

inverse: 4.75...0.25 VDC

inverse: 4.5...0.5 VDC

inverse: 20...4 mA

Resolution: typ ± 0.1 mm

Internal Cycle Time: 2 ms

Accuracy

Linearity: .1 mm

Hysteresis: ± 0.1 mm

Setpoint Tolerance: ? 1 mm

Operating conditions

Assembly orientation: In any direction

Operating temperature electronics, storage temp.: -40°C...+105°C

Fluid temperature: -30°C...+85°C

Dew point, humidity: 90 % rel. humidity, no condensation acc. EN60068-2-30

Pressure

Operating pressure ratings:

Pressure impulse test acc.

Ø 10 mm sensor rod

PN: 350 bar

Pmax: 450 bar DIN EN ISO 19879

IP rating sensor housing

Sensor housing: IP67, EN60529

Environmental testing:

Shock:

Vibration:

EMC:

IEC-68-2-27

100 g (6 ms) single hit

50 g (11 ms) at 1000 Shocks per axis

IEC 68-2-6 (10...2000 Hz)

Ø 10 mm sensor rod 15g (r.m.s)

ISO 14982 agricultural and forestry machines

ISO 11452-2 (radiated immunity) (Increased immunity voltage output 100V/m)

ISO 11452-4 (conducted immunity)

ISO 7637-1/2 (transient Impulses)

Materials and dimensions

Sensor rod:

Housing:

Mechanical assembly:

Stainless steel 1.4306 / AISI 304L (Ø 10 mm)

Stainless steel 1.4305 / AISI 303

Flange housing Ø 48 mm

O-ring 40.87 x 3.53 mm NBR 80, backup ring 42.6 x 48 x 1.4 PTFE

Electrical installation

Connector:

Supply voltage:

Voltage supply ripple:

Power drain:

Electric strength:

Over voltage protection (GND - VDC):

Polarity protection (GND - VDC):

Load:

Connector System 2 x M12x1 with O-ring 7 x 1.35 mm NBR 70

Connecting flange brass nickel-plated with O-ring 13 x 1.6 NBR 70

12/24 VDC (tolerance range 8 - 32 VDC)

< 1 % PP

< 1 W

500 VDC (DC ground to machine ground)

+ 36 VDC

up to -36 VDC

RL

? 10 k? mA output

RL

? 250 ? (12 VDC) VDC output

RL

? 500 ? (24 VDC) VDC output