BRAND : Mts Sensor
Input
Measured value Position
Stroke range 50…2500 mm (in 5 mm steps)
Output
Signal characteristic Analog output restricted by noise or A/D converter of control unit
Voltage 0.25…4.75 VDC / 0.5…4.5 VDC
Current 4…20 mA
Resolution Typ. 0.1 mm
Power up time Typ. 250 ms
Mounting zone 22 mm
Damping 36.5 / 63.5 mm
Accuracy
Linearity
0050…0250 mm ? ±0.1 mm,
0255…2000 mm ±0.04 % (F.S.),
2005…2500 mm ? ±0.8 mm
Repeatability ± 0.1 mm
Internal sample rate 2 ms
Setpoint tolerance ? 1 mm
Operating conditions
Mounting position Any
Operating temperature electronics ?40…+105 °C
Storage temperature ?25…+ 65 °C
Fluid temperature ?30…+ 85 °C
Dew point, humidity EN60068-2-30, 90 % rel. humidity, no condensation
Pressure
Operating pressure ratings Pressure impulse test according DIN EN ISO 19879
Pressure Pipe Ø 7 mm
Nominal operating pressure (Pn) 300 bar
Max. overload pressure in cylinder (Pmax) 400 bar
Max. static proof pressure in cylinder (Pproof) 525 bar
IP rating
M12 connector EN60529 (IP69K) when plugged
Sensor housing EN60529 (IP67)
Environmental testing
Shock test IEC 60068-2-27, 100 g (11 ms) single shock, 50 g (11 ms) at 1000 shocks per axis
Vibration test IEC 60068-2-64, 15 g (r.m.s.) Ø 7 mm pressure pipe (10…2000 Hz) – resonance frequencies excluded
EMC
...
Input
Measured value Position
Stroke range 50…2500 mm (in 5 mm steps)
Output
Signal characteristic Analog output restricted by noise or A/D converter of control unit
Voltage 0.25…4.75 VDC / 0.5…4.5 VDC
Current 4…20 mA
Resolution Typ. 0.1 mm
Power up time Typ. 250 ms
Mounting zone 22 mm
Damping 36.5 / 63.5 mm
Accuracy
Linearity
0050…0250 mm ? ±0.1 mm,
0255…2000 mm ±0.04 % (F.S.),
2005…2500 mm ? ±0.8 mm
Repeatability ± 0.1 mm
Internal sample rate 2 ms
Setpoint tolerance ? 1 mm
Operating conditions
Mounting position Any
Operating temperature electronics ?40…+105 °C
Storage temperature ?25…+ 65 °C
Fluid temperature ?30…+ 85 °C
Dew point, humidity EN60068-2-30, 90 % rel. humidity, no condensation
Pressure
Operating pressure ratings Pressure impulse test according DIN EN ISO 19879
Pressure Pipe Ø 7 mm
Nominal operating pressure (Pn) 300 bar
Max. overload pressure in cylinder (Pmax) 400 bar
Max. static proof pressure in cylinder (Pproof) 525 bar
IP rating
M12 connector EN60529 (IP69K) when plugged
Sensor housing EN60529 (IP67)
Environmental testing
Shock test IEC 60068-2-27, 100 g (11 ms) single shock, 50 g (11 ms) at 1000 shocks per axis
Vibration test IEC 60068-2-64, 15 g (r.m.s.) Ø 7 mm pressure pipe (10…2000 Hz) – resonance frequencies excluded
EMC
test & evaluation
ISO 14982 Agricultural and forest machines
EN 13309 Construction machines
Immunity: ISO 11452-2 (200 V/m Antenna), ISO 11452-4 (200 mA BCI)
Emissions: CISPR 16
Transiente Impulses: ISO 7637-2
E.S.D.: ISO/TR 10605
Materials and dimensions
Pressure pipe Stainless steel 1.4306 / AISI 304L
Housing Stainless steel 1.4305 / AISI 303
Sealing O-ring 23.47 ×2.62 mm NBR; Backup Ring 28 × 2 × 1.4 mm, Parker Parbaks 8-119 N1444-90 or 8-119 N0300-90
M12 connector insert Material: polyamide reinforces; O-ring 7 × 1.35 mm NBR 70; pins: brass with gold plated pins
M12 flange Brass nickel-plated with O-ring 13 × 1.6 NBR 70
Electrical installation
Connector M12 male plug or cable assembly
Supply voltage 12 VDC (8…32 VDC) 24 VDC (8…32 VDC)
Current consumption Typ. < 100 mA Typ. < 50 mA
Load (output VDC) RL> 10 k? RL> 10 k?
Load current (output VDC) Typ. 0.5 mA Typ. 0.5 mA
Loud (output mA) RL < 250 ? RL < 500 ?
Inrush current Max. 2.5 A/2 ms Max. 4.5 A/2 ms
Supply voltage ripple < 1 % p-p
Power drain < 1 W
Over voltage protection (GND-VDC) Up to +36 VDC
Polarity protection (GND-VDC) Up to ?36 VDC
Insulation Resistance R ? 10 M? @ 60 sec
Electric strength 500 VDC (DC GND to chassis GND)