BRAND : Mts Sensor
Input
Measured variables: Position
Measuring range: 72, 109, 128, 148, 162, 186, 194, 217, 250 mm
Output
Voltage: 0.5…4.5 VDC
Resolution: Continuous analog output restricted by noise or AD converter of control unit
Accuracy
Linearity: ± 0.15 mm
Hysteresis: ± 0.1 mm
Setpoint Tolerance: ± 1 mm
Operation conditions
Assembly orientation: In any direction
Storage temperature: -25 °C…+65 °C
Fluid temperature: -30 °C ... +85 °C
Operation temperature electronics, storage temp. : -40 °C…+105 °C
Pressure
Operating pressure ratings: Ø 8 mm sensor rod
PN : 250 bar
Pmax: 325 bar
IP rating
M12 connector DIN 40050 Part 9: IP69K in connected state
Environmental testing
Shock: IEC-60068-2-27, 50 g (11 ms) single hit,
50 g (11 ms) at 1000 shocks per axis
Vibration: IEC 60068-2-64 (10…2000 Hz) 15 g sinus
EMC: ISO 14982 Agricultural and forestry machines
radiated immunity ISO 11452-2 (antenna)
ISO 11452-5 (stripline)
radiated emission CISPR 12/16
ISO 7637-1: electric disturbance on vehicles
ISO/TR 10665 E.S.D.
Materials and dimensions
Sensor rod: Stainless steel 1.4306 / AISI 304L (Ø 8 mm )
Housing (electronics): Stainless steel 1.4305 / AISI 303
Pressure port: ISO 6149 Hexagon housing SW27 with M14 x 1,5
O-ring: 11,3 x 2,2 mm NBR 80
Electrical installation
Supply Vo...
Input
Measured variables: Position
Measuring range: 72, 109, 128, 148, 162, 186, 194, 217, 250 mm
Output
Voltage: 0.5…4.5 VDC
Resolution: Continuous analog output restricted by noise or AD converter of control unit
Accuracy
Linearity: ± 0.15 mm
Hysteresis: ± 0.1 mm
Setpoint Tolerance: ± 1 mm
Operation conditions
Assembly orientation: In any direction
Storage temperature: -25 °C…+65 °C
Fluid temperature: -30 °C ... +85 °C
Operation temperature electronics, storage temp. : -40 °C…+105 °C
Pressure
Operating pressure ratings: Ø 8 mm sensor rod
PN : 250 bar
Pmax: 325 bar
IP rating
M12 connector DIN 40050 Part 9: IP69K in connected state
Environmental testing
Shock: IEC-60068-2-27, 50 g (11 ms) single hit,
50 g (11 ms) at 1000 shocks per axis
Vibration: IEC 60068-2-64 (10…2000 Hz) 15 g sinus
EMC: ISO 14982 Agricultural and forestry machines
radiated immunity ISO 11452-2 (antenna)
ISO 11452-5 (stripline)
radiated emission CISPR 12/16
ISO 7637-1: electric disturbance on vehicles
ISO/TR 10665 E.S.D.
Materials and dimensions
Sensor rod: Stainless steel 1.4306 / AISI 304L (Ø 8 mm )
Housing (electronics): Stainless steel 1.4305 / AISI 303
Pressure port: ISO 6149 Hexagon housing SW27 with M14 x 1,5
O-ring: 11,3 x 2,2 mm NBR 80
Electrical installation
Supply Voltage: 12 VDC (tolerance range 9 - 15 VDC)
Power drain: < 1 W
Over voltage protection (GND-VDC) up to 30 VDC
Polarity protection: VDC - GND