BRAND : Mts Sensor
Measured Variables Displacement
Measuring Range 50 - 5000 mm
Output Voltage: 0...10 VDC or 10...0 VDC
(Minimum load: > 5 kOhm)
Current: 4(0)...20 mA or 20...4(0) mA
(Min/Max. 0 / 500 Ohm)
Start/Stop pulse: RS422 Differential signal
Adjustment of NULL and SPAN Analogue: 100% of measuring range (F.S.)
Resolution Analogue: Infinite, restricted by output ripple
Digital: 0,1 mm; 0,01 mm (controller depending)
Linearity < ± 0,02 % F.S. (Minimum ± 50 µm)
Repeatability < ± 0,001 % F.S.
Update Frequency Analogue: 1kHz / Digital: controller dependent
Connection Type Cable outlet
Input Voltage 24 VDC (-15 / +20 %)
Current Drain 100 mA typical
Ripple < 1 % peak to peak
Temperature Coefficient < 40 ppm/ ºC
Electric Strength 500 V (DC ground to machine ground)
Operating Temperature -40 ºC...+75 ºC
Dew Point, Humidity 90 % rel. humidity, no condensation
EMV-Test Electromagnetic emission EN 50081-2; Electromagnetic immunity EN 50082-2
EN 6100-4-2/3/4/6 Level 3/4 Criteria A,
LD-sensor installed in a ground metal housing
Shockrating 100 g, 6 ms / IEC-Standard 68-2-27
Vibration Rating 10 g, 10 - 2000 Hz / IEC-Standard 68-2-6
Mounting Any orientation
Magnet speed Any
Sensor rod + flange Stainless steel 1.4301 / AISI 304
- Pressure Rating 350 bar, 700 bar peak pressure
Sensor Electronic Housing Alum...
Measured Variables Displacement
Measuring Range 50 - 5000 mm
Output Voltage: 0...10 VDC or 10...0 VDC
(Minimum load: > 5 kOhm)
Current: 4(0)...20 mA or 20...4(0) mA
(Min/Max. 0 / 500 Ohm)
Start/Stop pulse: RS422 Differential signal
Adjustment of NULL and SPAN Analogue: 100% of measuring range (F.S.)
Resolution Analogue: Infinite, restricted by output ripple
Digital: 0,1 mm; 0,01 mm (controller depending)
Linearity < ± 0,02 % F.S. (Minimum ± 50 µm)
Repeatability < ± 0,001 % F.S.
Update Frequency Analogue: 1kHz / Digital: controller dependent
Connection Type Cable outlet
Input Voltage 24 VDC (-15 / +20 %)
Current Drain 100 mA typical
Ripple < 1 % peak to peak
Temperature Coefficient < 40 ppm/ ºC
Electric Strength 500 V (DC ground to machine ground)
Operating Temperature -40 ºC...+75 ºC
Dew Point, Humidity 90 % rel. humidity, no condensation
EMV-Test Electromagnetic emission EN 50081-2; Electromagnetic immunity EN 50082-2
EN 6100-4-2/3/4/6 Level 3/4 Criteria A,
LD-sensor installed in a ground metal housing
Shockrating 100 g, 6 ms / IEC-Standard 68-2-27
Vibration Rating 10 g, 10 - 2000 Hz / IEC-Standard 68-2-6
Mounting Any orientation
Magnet speed Any
Sensor rod + flange Stainless steel 1.4301 / AISI 304
- Pressure Rating 350 bar, 700 bar peak pressure
Sensor Electronic Housing Aluminium diecasting housing
Sealing IP 65
Sensor Installation Fitting flange or thread M18 x 1,5
Magnet Type Ring magnet