BRAND : Mts Sensor
Input
Measured value Position
Stroke range 500…5000 mm (in 20 mm steps)
Output
Signal characteristic Analog output restricted by noise or A/D converter of control unit
Voltage 0.25…4.75 VDC / 0.5…4.5 VDC
Current 4…20 mA
Resolution ±0.2 mm
Sample rate 2 ms
Accuracy
Linearity ±0.04 % (F.S.)
Repeatability ±0.005 % (F.S.)
Hysteresis ±0.2 mm
Operating conditions
Mounting position Any
Operating temperature ?40…+105 °C
Humidity 90 % rel. humidity, no condensation
Ingress protection IP67 / IP69K with appropriate mating connection
Pressure
Nominal operating pressure (Pn) 350 bar
Max. overload pressure in cylinder (Pmax) 450 bar
Max. static proof pressure in cylinder (Pproof) 625 bar
Environmental testing
Shock test IEC 60068-2-27, 100 g (6 ms) single shock, 50 g (11 ms) at 1000 shocks per axis
Vibration test IEC 60068-2-64, 2 g (5…2000 Hz)
EMC test & evaluation ISO16750-2:2010
ISO 14982:2009 - Agricultural and forestry machinery
ISO 13766:2006 - Earth-moving machinery
EN 13309:2010 - Construction machinery
RF immunity to 200 V/m per ISO 11452-2/-4
Materials and dimensions
Sensor rod with flange Stainless steel 1.4306 (AISI 304L)
Sensor electronics housing Stainless steel 1.4305 (AISI 303)
Electrical installation
Connector M12 male plug
Supply voltage 12 VDC (tolerance ...
Input
Measured value Position
Stroke range 500…5000 mm (in 20 mm steps)
Output
Signal characteristic Analog output restricted by noise or A/D converter of control unit
Voltage 0.25…4.75 VDC / 0.5…4.5 VDC
Current 4…20 mA
Resolution ±0.2 mm
Sample rate 2 ms
Accuracy
Linearity ±0.04 % (F.S.)
Repeatability ±0.005 % (F.S.)
Hysteresis ±0.2 mm
Operating conditions
Mounting position Any
Operating temperature ?40…+105 °C
Humidity 90 % rel. humidity, no condensation
Ingress protection IP67 / IP69K with appropriate mating connection
Pressure
Nominal operating pressure (Pn) 350 bar
Max. overload pressure in cylinder (Pmax) 450 bar
Max. static proof pressure in cylinder (Pproof) 625 bar
Environmental testing
Shock test IEC 60068-2-27, 100 g (6 ms) single shock, 50 g (11 ms) at 1000 shocks per axis
Vibration test IEC 60068-2-64, 2 g (5…2000 Hz)
EMC test & evaluation ISO16750-2:2010
ISO 14982:2009 - Agricultural and forestry machinery
ISO 13766:2006 - Earth-moving machinery
EN 13309:2010 - Construction machinery
RF immunity to 200 V/m per ISO 11452-2/-4
Materials and dimensions
Sensor rod with flange Stainless steel 1.4306 (AISI 304L)
Sensor electronics housing Stainless steel 1.4305 (AISI 303)
Electrical installation
Connector M12 male plug
Supply voltage 12 VDC (tolerance range 8…32 VDC) 24 VDC (tolerance range 8…32 VDC)
Current consumption Typ. < 100 mA Typ. < 50 mA
Load (output VDC) RL> 10 k? RL> 10 k?
Load current (output VDC) Typ. 1 mA Typ. 1 mA
Loud (output mA) RL < 250 ? RL < 500 ?
Inrush current Max. 2.5 A/2 ms Max. 4.5 A/2 ms
Supply voltage ripple < 1 % PP
Power drain < 1 W
Over voltage protection (GND-VDC) Up to +36 VDC
Polarity protection (GND-VDC) Up to ?36 VDC
Insulation Resistance R ? 10 M? @ 60 sec
Electric strength 500 VDC (DC GND to chassis GND