BRAND : Mts Sensor
nput
Measured value: Position
Stroke length: 72, 109, 128, 148, 162, 186, 194, 217, 250 mm
Output
Voltage: 0.1 - 4.9 VDC
Resolution: analog output signal
Signal without magnet: not specified
Feature: At 5 VDC operating voltage output is ratiometric to operating voltage
Accuracy
Linearity: ± 0.15 mm by means of magnet 401842, between 5 % and 95 % of stroke length
Zero tolerance: ± 1 mm
Hysteresis: ± 25 µm
Repeatability: ± 25 µm
Temperature coefficient: ± 0.005 % per °C
Update time: 500 Hz (2 ms)
Operation conditions
Operating temperature: -40 °C…+75 °C
Storage temperature: -20 °C…+85 °C
Pressure
up to 2500 m altitude
IP Protection
IP30
3 - DIN 40 050 Part 9 – Protection against foreign bodies – Protected against foreign bodies from Ø 2.5 mm
0 - DIN 40 050 Part 9 – Protection against water – No protection
Environmental testing
Shock test: IEC-68-2-27
10 g (11 ms) –> Single hit
10 g (11 ms) 1000 shocks per axis
Vibration test: IEC 60068-2-6 (10…2000 Hz) 10 g Sinus (resonance frequencies excluded)
EMC-test: Emission according to EN 61000-6-4
CISPR 16-2-3 – Disturbance field strength (measurement distance 3 m)
CIPSR 16-2-1 – Disturbance current (DC voltage supply)
Immunity according to EN 61000-6-2
EN 61000-4-2 – Electrostatic discharge (ESD) (Compliance only with...
nput
Measured value: Position
Stroke length: 72, 109, 128, 148, 162, 186, 194, 217, 250 mm
Output
Voltage: 0.1 - 4.9 VDC
Resolution: analog output signal
Signal without magnet: not specified
Feature: At 5 VDC operating voltage output is ratiometric to operating voltage
Accuracy
Linearity: ± 0.15 mm by means of magnet 401842, between 5 % and 95 % of stroke length
Zero tolerance: ± 1 mm
Hysteresis: ± 25 µm
Repeatability: ± 25 µm
Temperature coefficient: ± 0.005 % per °C
Update time: 500 Hz (2 ms)
Operation conditions
Operating temperature: -40 °C…+75 °C
Storage temperature: -20 °C…+85 °C
Pressure
up to 2500 m altitude
IP Protection
IP30
3 - DIN 40 050 Part 9 – Protection against foreign bodies – Protected against foreign bodies from Ø 2.5 mm
0 - DIN 40 050 Part 9 – Protection against water – No protection
Environmental testing
Shock test: IEC-68-2-27
10 g (11 ms) –> Single hit
10 g (11 ms) 1000 shocks per axis
Vibration test: IEC 60068-2-6 (10…2000 Hz) 10 g Sinus (resonance frequencies excluded)
EMC-test: Emission according to EN 61000-6-4
CISPR 16-2-3 – Disturbance field strength (measurement distance 3 m)
CIPSR 16-2-1 – Disturbance current (DC voltage supply)
Immunity according to EN 61000-6-2
EN 61000-4-2 – Electrostatic discharge (ESD) (Compliance only with corresponding protection housing, see H2 and M1)
EN 61000-4-3 – Radiated electrosolenoidic radio-frequency, free radiated (Compliance only with corresponding protection
housing, see H2 and M1)
EN 61000-4-4 – Electrical fast transient (Burst)
EN 61000-4-5 – Surge
EN 61000-4-6 – Conducted radio-frequency, line guided
EN 61000-4-8 – Power frequency solenoidic field
Form factor, material
Housing: POM
Protective pipe: nylon blue
Electrical connection
Supply voltage: CS: 5 VDC (tolerance range 4.75 - 5.5 VDC), CM: 12 VDC (tolerance range 9 - 15 VDC)
Max. power consumption: max. 40 mA
Output load: analog: > = 10 k?
Overvoltage protection: CS: up to 19 VDC short term
CM: up to 29 VDC short term
Polarity protection: VDC - GND
Operating voltage quality: CS: 5 VDC CM: 12 VDC
Load control: ± 0.1 % ± 0.15 %
Grid control: ± 0.05 % ± 0.05 %
Ripple: < 50 mVpp < 100 mVpp
Mechanical connection
Screw connection: 2 screws M3 x 37, max. tightening torque 0.4 Nm, with 3 mm bore hole
Terminal connection: by means of O-rings (consultation with MTS required)