What are you looking for?

Meggitt Vibro-Meter VM600 IOCR Input/Output Card for CPUR Card

BRAND : Meggitt

Type Designation Ordering number (PNR)

IOCR Input/output card for the CPUR 601-002-000-VVV

Input/output card for VM600 CPUR rack controller and communications interface card.

The VM600 CPUR and IOCR rack controller and communications interface card pair is a central processing unit (CPU) card pair that acts as a system controller and data communications gateway for a VM600 rack-based machinery protection system (MPS) and/or condition monitoring system (CMS) from Meggitt’s Vibro-Meter® product line.

Details

Type Designation Ordering number (PNR)

IOCR Input/output card for the CPUR 601-002-000-VVV

Input/output card for VM600 CPUR rack controller and communications interface card.

The VM600 CPUR and IOCR rack controller and communications interface card pair is a central processing unit (CPU) card pair that acts as a system controller and data communications gateway for a VM600 rack-based machinery protection system (MPS) and/or condition monitoring system (CMS) from Meggitt’s Vibro-Meter® product line.

Features
  • Input/output (interface) card for CPUR card
  • PARAMETER

    VALUE (IMPERIAL | METRIC)

    Monitoring system (application)

    Machinery protection, condition monitoring, combustion monitoring

    VM600 system function

    Common

    VM600 system component

    Processing card

    VM600 component function

    Rack controller and communications interface

    VM600 component and rack compatibility

    ABE040, ABE042

    VM600 communications interfaces

    Modbus RTU/TCP

    VM600 rack alarm reset (AR)

    No

    VM600 MPS rack (CPUx) security

    No

    VM600 event logs

    System event and measurement event logs (up to 1000)

    VM600 output relays

    5