BRAND : Meggitt
Signal conditioner for use with accelerometers (CA) and dynamic pressure sensors (CP).
The IPC707 signal conditioner is a high-quality, high-reliability charge-converter for use with piezoelectric sensors: CA accelerometers and CP dynamic pressure sensors.
The IPC707 is highly configurable (transfer function with optional integration, transfer sensitivity, high-pass and low-pass filtering, and optional diagnostic circuitry), and provides either a current output or a voltage output. It is compatible with different piezoelectric materials and replaces the previous versions of the IPC704 signal conditioner (PNR 244-704-000-xxx).
The IPC707 is designed and built for long-term use in environments characterised by hazardous areas (potentially explosive atmospheres). It is also designed for use in safety-related applications (functional safety contexts/systems) such as SIL 2 in accordance with IEC 61508 and PL c Cat 1 in accordance with ISO 13849-1.
Note: The IPC707 signal conditioner is a form, fit and functionally equivalent replacement (fully backward compatible) for the IPC704 signal conditioner and earlier IPCxxx signal conditioners, that matches or betters the outstanding measurement specifications of the IPC704. The IPC707 also adds a number of signifi...
Signal conditioner for use with accelerometers (CA) and dynamic pressure sensors (CP).
The IPC707 signal conditioner is a high-quality, high-reliability charge-converter for use with piezoelectric sensors: CA accelerometers and CP dynamic pressure sensors.
The IPC707 is highly configurable (transfer function with optional integration, transfer sensitivity, high-pass and low-pass filtering, and optional diagnostic circuitry), and provides either a current output or a voltage output. It is compatible with different piezoelectric materials and replaces the previous versions of the IPC704 signal conditioner (PNR 244-704-000-xxx).
The IPC707 is designed and built for long-term use in environments characterised by hazardous areas (potentially explosive atmospheres). It is also designed for use in safety-related applications (functional safety contexts/systems) such as SIL 2 in accordance with IEC 61508 and PL c Cat 1 in accordance with ISO 13849-1.
Note: The IPC707 signal conditioner is a form, fit and functionally equivalent replacement (fully backward compatible) for the IPC704 signal conditioner and earlier IPCxxx signal conditioners, that matches or betters the outstanding measurement specifications of the IPC704. The IPC707 also adds a number of significant improvements, including:
PARAMETER |
VALUE
(IMPERIAL | METRIC) |
Output type |
Current (2-wire) or voltage (3-wire) |
Measurement system |
CA vibration or CP dynamic pressure |
Sensor |
CA accelerometers or CP dynamic
pressure sensors |
Sensitivity |
See transfer function characteristics
in data sheet |
Frequency range |
0.5 to 20000 Hz |
Linearity |
<0.2% |
Operating temperature range |
?40 to 185 °F | ?40 to 85 °C |
Protection rating |
IP40 |
Hazardous area certifications |