What are you looking for?

Meggitt Vibro-Meter CP216 Piezoelectric Pressure Transducer

BRAND : Meggitt

  • Type Designation Cable length Ordering number
  • CP216 Piezoelectric pressure Defined when ordering 143-216-000-011
  • transducer with LEMO connector 0.5 m 143-216-000-021
  • 1 m 143-216-000-031
  • 2 m 143-216-000-041
  • 3 m ...

Details

  • Type Designation Cable length Ordering number
  • CP216 Piezoelectric pressure Defined when ordering 143-216-000-011
  • transducer with LEMO connector 0.5 m 143-216-000-021
  • 1 m 143-216-000-031
  • 2 m 143-216-000-041
  • 3 m 143-216-000-051
  • CP216 Piezoelectric pressure transducer with
  • Vibro-Meter high-temperature connector Defined when ordering 143-216-000-111
  • 0.5 m 143-216-000-121
  • 1 m 143-216-000-131
  • 2 m 143-216-000-141
  • 3 m 143-216-000-151
  • 5 m 143-216-000-161
  • 200 pC/bar, ?54 to 470 °C, 2 to 15000 Hz.

    The CP216 piezoelectric pressure transducer is a high-quality, high-reliability dynamic pressure sensor with a piezoelectric sensing element that provides a charge output. Accordingly, an external charge amplifier (IPC704 signal conditioner), is required to convert this charge-based signal into a current or a voltage signal.

    The CP216 is designed and built for long-term use in extreme environments characterised by high temperatures and/or hazardous areas (potentially explosive atmospheres).

    Features
    • Designed for the long-term measurement of pressure pulsation in extreme environments, such as gas turbine combustors
    • High sensitivity: 200 pC/bar
    • Very high frequency response: up to 15000 Hz
    • Available in different integral mineral-insulated (MI) cable lengths, terminated with either a high-temperature connector or a LEMO connector
    • Certified for use in potentially explosive atmospheres
    • PARAMETER

      VALUE (IMPERIAL | METRIC)

      Output type

      Charge (2-wire)

      Sensitivity

      13.8 pC/psi | 200 pC/bar

      Operating temperature range

      ?65 to 878 °F | ?54 to 470 °C

      Frequency response

      Up to 15000 Hz

      Sensitivity deviation

      See response curves in data sheet

      Dynamic measurement range

      0.007 to 3625 psi | 0.0005 to 250 bar

      Overload capacity

      Up to 5076 psi | Up to 350 bar

      Linearity

      <±1%

      Acceleration sensitivity

      ?0.05 pC/g

      Resonant frequency

      >80 kHz

      Hazardous area certifications

      Ex ib