What are you looking for?

Leine Linde ESR 125 Strain sensor Strain sensor and components for digitalized strain measurement

BRAND : Leine Linde

The robust and precise ESR strain sensor can be used permanently or in measurement campaigns. It provides digitalized strain measurement data directly into the machine controller or data acuquisition system.With help from gateways, the sensor can provide data via fieldbus interfaces including wireless LAN-based OPC UA.

Thanks to the specially developed measurement principle, the strain sensor comes with an inbuilt temperature compensation and stress-free measurement, which allows nearly unlimited time of operation.

By use of the bi-directional digital data interface, the sensor provides further information as of temperature, type label, and internal sensor diagnostics. Furthermore it is possible to store application-specific information into each sensor to allow e.g. automatic machine start procedures.

Different variants are available in order to allow the easiest possible fixation: adhesive installation, screw installation, or magnet installation.

Details

The robust and precise ESR strain sensor can be used permanently or in measurement campaigns. It provides digitalized strain measurement data directly into the machine controller or data acuquisition system.With help from gateways, the sensor can provide data via fieldbus interfaces including wireless LAN-based OPC UA.

Thanks to the specially developed measurement principle, the strain sensor comes with an inbuilt temperature compensation and stress-free measurement, which allows nearly unlimited time of operation.

By use of the bi-directional digital data interface, the sensor provides further information as of temperature, type label, and internal sensor diagnostics. Furthermore it is possible to store application-specific information into each sensor to allow e.g. automatic machine start procedures.

Different variants are available in order to allow the easiest possible fixation: adhesive installation, screw installation, or magnet installation.

Technical dataµ?=µm/m
Measuring step0.025 µ?
Measuring range± 5 000 µ?
Permissible mechanical working range± 17 500 µ?
Vibration? 200 m/s2
Shock? 300 m/s2
Encapsulation level IP66
Operating temperatureVariants up to -40°C...+100°C
Cover materialAluminium