What are you looking for?

Lamtec LT3-EX Lambda Transmitter

BRAND : Lamtec

Details

Measuring range :O2: 0 - 21 % (configurable)
Housing:Sheet steel
Protection type following DIN 40050IP66, without display
IP54
Dimensions (HxBxT) mm300 x 300 x 120
ColorGrey, RAL 7035
WeightAppr. 6kg
Ambient temperature
operation:
-5 °C ... + 60 °C
Ambient temperature
transport and storage:
-20 °C ... + 70 °C
Power supply:120 VAC / -30%...230 VAC / +10%, 50...60Hz
Power consumption:30W (normal operation)
69W (heating)
Resolution O2:

0,1 Vol. % O2

Preciseness of measuring:
(with combination probe KS1D)
O2: ±5% of measurement value
(max ± 0,3 Vol. % O2)
Setting time (60 % time):O2: T 60 < 3 s (unfiltered)
Time for readiness
with probe LS2 (cold start-up)
Appr. 10min after „POWER ON“
(Initial start-up appr. 60min)
Analogue output, via analogue output module:Analogue output 1 (O2 measurement value)
- Range of setting: 0…25 % O2
- Factory setting 0…10 Vol.% O2 -> 4…20 mA
Digital outputs
via digital output module:
Optional
Control element:Integrated LT3 User Interface with LCD-graphic display 45x27 mm (BxH)
External start-up assistant with LCD-graphic display 60x32 mm (BxH) (Option)
Interface:LAMTEC System Bus (LSB)