What are you looking for?

JUMO dTRANS p02 - Pressure Transmitter with Display (404385)

BRAND : JUMO

Features

Details

Features

  • Medium temperature: -40 to +200 °C (SIP and CIP capable)
  • Local operation (keyboard/LCD) or operation through easy, digital communication (HART protocol) possible
  • LCD signals occurs if the measuring range is exceeded or not met; signaling also occurs in the event of sensor exceedance and sensor faults
  • Fully welded measuring system
  • Accessories: pressure separator, valves, setup program
  • Measuring ranges: -100 to 100 mbar – -1 to 600 bar relative, 0 to 600 mbar – 0 to 25 bar absolute
  • For relative pressure, absolute pressure, and level
  • For non-aggressive and aggressive gases, vapors, and liquids
  • High linearity: ? 0.1 % from end value
  • Excellent long-term stability: < 0.1 % per year
  • Excellent temperature compensation
  • ATEX approval available as an option


Depiction through the display

  • Pressure in 13 different units; measured value in %, or scaled with a choice of measuring unit
  • Output current in mA
  • Sensor temperature in °C or °F
  • Measured value error, measured value outside of measuring range
  • Minimum pressure and maximum pressure (drag indicator)
  • Pressure and sensor temperature can be displayed simultaneously

Settings via the operating keys

  • Zero point correction
  • Start and end of measuring without pressure specification (blind setting) or with pressure specification: simple, time-saving, convenient
  • Attenuation
  • Current-generator function
  • Output signal in event of malfunction: adjustable to 3.85 mA or 21.5 mA
  • Lock function for keys
  • Reset function for minimum and maximum measured values (drag indicator)
  • Density correction for various measuring media
  • Measuring units for pressure and temperature

Customer benefits

  • Process reliability
    The parts coming into contact with the medium made of stainless steel (optionally made of NiMo alloy or Monel with the use of a pressure separator) and a system that is cavity-free reflect the resistance to aggressive media (among other things). The measuring device has a high degree of precision with a deviation from characteristic line of 0.1 % and offers an excellent long-term stability of < 0.1 % per year. The high-temperature version guarantees safe application in SIP and CIP systems.
  • Uncomplicated and time-saving
    The measuring device can be operated reliably and easily either on site or set through a more easy-to-use setup program (HART interface).

Applications

  • Food and beverage industry
  • Pharmaceutical industry
  • Chemical and petrochemical industries
  • Water and wastewater engineering
  • Paper manufacturing
  • Oil and gas industry
  • Power stations

Other Suggested Products