Details
Features
- Measuring ranges: 0 to 60 mbar DP to 0 to 25 bar DP
- For differential pressure, filling level, and flow
- For non-aggressive and aggressive gases, vapors, and liquids
- Temperature of medium: -40 to +100 °C
- Linearity: ? 0.1 % of end value
- Excellent long-term stability of < 0.1 % per year
- Load on one and both sides up to a static pressure of 160 bar; up to 420 bar as an option
- Excellent temperature compensation
- Operation on site or using HART protocol
- Signaling occurs if the measuring range is exceeded or not met; signaling also occurs in the event of sensor exceedance and sensor faults
- Accessories: pressure separator, valves, setup program
- ATEX approval available as an option
Display on the display
- Pressure in 13 different units; measured value in % or scaled with a choice of measuring unit
- Output current in mA
- Sensor temperature in °C or °F
- Measured value error, measured value outside of measuring range
- Minimum pressure and maximum pressure (drag indicator)
- Pressure and sensor temperature can be displayed simultaneously
Settings via the operating keys
- Zero point correction
- Start and end of measuring without pressure specification (blind setting) or with pressure specification: simple, time-saving, convenient
- Attenuation
- Current-generator function
- Output signal in event of malfunction: adjustable to 3.85 mA or 21.5 mA
- Lock function for keys
- Reset function for minimum and maximum measured values (drag indicator)
- Linear / square-rooted characteristic line
- Density correction for various measuring media
- Measuring units for pressure and temperature
Customer benefits
Applications
- Water and wastewater technology
- Paper production
- Oil and gas industry
- Power stations
- Chemical and petrochemical industries
- Food and beverage industry
- Pharmaceutical industry