Performance Level according to EN ISO 13849-1:2008 | e / Kategorie 3 |
---|
Safety Integrity Level (SIL) according to EN 62061:2005 | 3 |
---|
Functions Input | 1 switching strip |
---|
Functions Output | 1 output with 2 relays each with 1 NC contact |
---|
Additional functions | Changeover contact approx. 0.5 s time delayed |
---|
Supply voltage A1 – A2 | 230 V AC |
---|
Rated power | 3 VA |
---|
Power pack potential-isolated | yes |
---|
Relay contacts 13 – 14; 21 – 24 max. switching voltage AC/DC | 250 V/24 V |
---|
Relay contacts 13 – 14; 21 – 24 max. switching current AC/DC | 4 A/2 A |
---|
Perm. operating temperature | –20..+55 °C |
---|
Housing dimensions (W x H x D) in mm | 45 x 75 x 120 |
---|
Degree of protection for housing/contacts | IP 40/IP 20 |
---|
Weight | 390 g |
---|
Tests | EN ISO 13849-1:2008, EN 62061:2005 |
---|