IDP05S
|
FUNCTION:
Value Differential Pressure Transmitter. Measures the difference
between two pressures and transmits a proportional or square root (Flow)
Electrical Signal. Accuracy expressed as percentage of span.
|
T
|
ELECTRONICS
VERSION AND OUTPUT SIGNAL: HART & 4 To 20 mA
|
F1
|
STRUCTURE
CODE: Prepared For Schneider Direct Connect Seal On High Side (Flanged
PSFLT Or Sanitary PSSCT Or PSSST) & 1/2 NPT Connection on Low Side;
Silicone Fill In Sensor
|
B
|
SPAN
LIMITS: 0.5 and 200 inH2O; 0.12 and 50 kPa; 1.2 and 500 mbar
|
0
|
PROCESS
CONNECTOR: (Matl Same As Process Cover) 1/2 NPT 316 ss,
Process Connector On Low Side
|
3
|
CONDUIT
CONNECTION & HOUSING MATERIAL: 1/2 NPT Conduit
Connection, Both Sides, 316 ss Housing
|
AA
|
ELECTRICAL
SAFETY: ATEX Intrinsically Safe; II 1 GD, EEx ia IIC, Zone 0
|
L1
|
OPTIONAL
MODEL SUFFIX(ES) INCLUDED: Digital Display,
Pushbuttons, And Window Cover
|