What are you looking for?

Firestone W01-358-0017 Actuator

BRAND : Firestone

Maximum Diameter @ 100 PSIG (inches)

6

Details

Maximum Diameter @ 100 PSIG (inches)

6

Maximum Height (inches)

3.3

Maximum Stroke (inches)

1.4

Minimum Usable Height (inches)

1.9

Force @ 80PSI at Stroke of 1 Inch (pounds)

930

Force @ 80PSI at Stroke of Maximum Stroke (pounds)

580

Material

2-Ply Standard Cord

END CLOSURE DETAILS

Bead ring Type

4

Bolt Circle Diameter (inches)

4.5

# of Bolts (each ring)

6

AIRMOUNT ISOLATOR

Design Height

3

Load (at Design Height) at: 40 psig (pounds)

420

Load (at Design Height) at: 60 psig (pounds)

640

Load (at Design Height) at: 80 psig (pounds)

880

Natural Frequency (@80 psig) (cpm)

237

% of Isolation at Forced Frequency 800 CPM

90.3

% of Isolation at Forced Frequency 1500 CPM

97.4