Details
Switching amplifier with electronic and relay output
The type 8582 isolating switching amplifier converts binary signals from sensors into switching signals that meet practically all requirements in the sector of electric railways or allow simple adaptation.
Technical data
|
Dimensions
|
see figure, WxHxD 145x70x112
|
|
mm
|
Housing
|
ABS / polycarbonate
|
Attachment
|
2 drilled holes as per the drilling
|
|
template
|
|
Standard carrying rail in accordance
|
|
with
DIN EN 50022
|
Type of protection
|
Housing: IP 40; terminals: IP 20
|
Connections
|
2 X
2.5 mm2 solid as per
DIN 46288
|
|
or
2 x 1.5 mm2 with
sleeve
|
Ambient temperature
|
-20°C to +60°C
|
Supply voltage
|
Terminal 31 (L1); terminal 27 (L2)
|
|
DC
150 V to DC 900 V
|
|
AC
115 V to AC 600 V
|
Power drawn
|
max. 8 W
|
Sensor connection
|
resistant to short-circuits, termi-
|
|
nal
11 (*); terminal 12 (-)
|
Nominal voltage
|
DC 12 V
|
Max. current (1k)
|
approx.
25 mA
|
Switching point
|
11
mA ± 1 mA
|
Hysteresis
|
approx.
4.5 mA
|
Initiation delay
|
approx. 1 s (other values on
|
|
request)
|
Relay output
|
1 make-type contact (zero-potenti-
|
|
al, terminals 2,4 (K1) with varistor
|
|
protective switching
|
Voltage
|
max. DC 900 V
|
Current
|
max. 3A
|
Power
|
max.
50 W
|
Relay output
|
1 make-type contact (zero-potential),
|
|
terminals 8,9 (K2)
|
|
AC 250 V 4.0 A cos?
> 0.7
|
|
DC 120 V 1.0 A ohmic load
|
Electronic output
|
Terminals 14,15 (K3), resistant to
|
|
short-circuiting
|
Nominal voltage
|
DC 12 V
|
Current
|
max. 20 mA
|
Max. current (Ik)
|
approx.
35 mA
|
Test voltages
|
Supply voltage ? inputs/outputs 6 kVe?
|
|
Output terminal ? inputs/outputs
|
|
6
kVe?
|
|
Output
K2 ? sensor/K3 4 kVe?
|
|
There is no galvanic separation
|
|
between the sensor connection and
|
|
the electronic switching output.
|
Accessories
|
see brochure sheets 8432, 8433
|
Temperature
monitor
|
and 8434
|
Ordering information
|
Type 8582 00
|
Part No. 420200
|
|