BRAND : ESN
Control Unit switch panel housing version, with pulse extension and running-time limitation
The type 8513 control unit serves the purposes of power supply, remote control, function monitoring, and switch-position reporting on switch drive motors based on the 3-lead principle (inwards lead, outwards lead, and return lead).
Technical Data Control Unit switch panel housing version, with pulse extension and running-time limitation The type 8513 control unit serves the purposes of power supply, remote control, function monitoring, and switch-position reporting on switch drive motors based on the 3-lead principle (inwards lead, outwards lead, and return lead). Technical Data Dimensions housing W/H/D = 136x90x125 mm front frame W/H/D = 146x98x35 mm Housing Noryl, ABS Fastening 2 clamps Safety category Housing IP 40; Terminals IP 10 Ambient temperature -20°C to +60°C Fuse / breaker as required (standard = 6.3A) Command buttons 2 (for “On”
and “O?”) Contact connection max. AC 250V, 5.0A Indicators 2 light-emitting diodes Colours:
red, yellow, green or to customer’s specification (standard:
“On” = red, “O?” = green) 1 zero-potential switch contact for “On”, 1 for “O?” U
? AC 250V; I ? 2A; P ? 500 VA Remote control con- nections Consumption approx. 250
mW Voltage DC 24V (19-34V) Timings Impulse extension = running time limitation Standard: approx. 10 seconds (adjustable, 1-15 seconds) Test voltage Field side against indicator contact and Field side against control side 4
kVe? (1
minute) MTBF ground fixed at
case temperature ?
40 °C: 125.000h Ordering Information Type 8513 Order No. 310251 |