Control Unit with/without pulse extension and running-time limitation

The Type 8513 control unit serves the purposes of power supply, remote control, function monitoring, and switch-position reporting on switch drive motors based on the 3-lead principle (inwards lead, outwards lead, and return lead).

Details

Control Unit with/without pulse extension and running-time limitation

The Type 8513 control unit serves the purposes of power supply, remote control, function monitoring, and switch-position reporting on switch drive motors based on the 3-lead principle (inwards lead, outwards lead, and return lead).

Technical Data

Technical Data

Dimensions

W/H/D = 100/70/115 mm

Housing

ABS / polystyrol

Fastening

2 drilled holes as in drilling diagram

Safety category

Housing IP 40; Terminals IP 10

Ambient temperature

-20°C to +60°C

Fuse / breaker

as required (standard = 6.3A)

Command buttons

2 (for “On” and “O?”)

Contact connection

max. AC 250V, 5.0A

Indicators

2 light-emitting diodes

Colours: red, yellow, green or to

customer’s specification

(standard: “On” = red, “O?” = green)

1 zero-potential switch contact

for “On”, 1 for “O?”

U ? AC 250V; I ? 2A; P ? 500 VA

Remote control con-

nections

Consumption

approx. 250 mW

Voltage

DC 24 V (19 - 34 V)

? 8513 01 / ? 8513 11

DC 60 V (38 - 86 V)

? 8513 02 / ? 8513 12

DC 110 V (88 -120 V)

? 8513 03 / ? 8513 13

Timings

Impulse extension = running time

limitation

Standard: approx. 10 seconds (adju-

stable, 1-15 seconds)

Test voltage

Field side against indicator contact

and Field side against control side

4 kVe? (1 minute)

without pulse exten-

? 8513 0-

sion and running-time

limitation

with pulse extension

? 8513 1-

and running-time

limitation

Ordering Information

Type

Order No.

8513 01

310200

8513 02

310202

8513 03

310204

8513 11

310201

851312

310203

851313

310205